The study proposed a noninvasive approach based on comparing atrial vectorcardiogram loops to differentiate between the most common forms of right and left macroreentrant atrial tachyarrhythmias. Results showed effectiveness in identifying different types of arrhythmias and predicting the existence and location of a slow conduction zone.
Background and objectives: Macroreentrant atrial tachyarrhythmias (MRATs) can be caused by different reentrant circuits. The treatment for each MRAT type may require ablation at different sites, either at the right or left atria. Unfortunately, the reentrant circuit that drives the arrhythmia cannot be ascertained previous to the electrophysiological intervention. Methods: A noninvasive approach based on the comparison of atrial vectorcardiogram (VCG) loops is proposed. An archetype for each group was created, which served as a reference to measure the similarity between loops. Methods were tested in a variety of simulations and real data obtained from the most common right (peritricuspid) and left (perimitral) macroreentrant circuits, each divided into clockwise and counterclockwise subgroups. Adenosine was administered to patients to induce transient AV block, allowing the recording of the atrial signal without the interference of ventricular signals. From the vectorcardiogram, we measured intrapatient loop consistence, similarity of the pathway to archetypes, characterisation of slow velocity regions and pathway complexity. Results: Results show a considerably higher similarity with the loop of its corresponding archetype, in both simulations and real data. We found the capacity of the vectorcardiogram to reflect a slow velocity region, consistent with the mechanisms of MRAT, and the role that it plays in the characterisation of the reentrant circuit. The intra-patient loop consistence was over 0.85 for all clinical cases while the similarity of the pathway to archetypes was found to be 0.85 +/- 0.03, 0.95 +/- 0.03, 0.87 +/- 0.04 and 0.91 +/- 0.02 for the different MRAT types (and p < 0 . 02 for 3 of the 4 groups), and pathway complexity also allowed to discriminate among cases (with p < 0 . 05 ). Conclusions: We conclude that the presented methodology allows us to differentiate between the most common forms of right and left MRATs and predict the existence and location of a slow conduction zone. This approach may be useful in planning ablation procedures in advance. (c) 2021 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license ( http://creativecommons.org/licenses/by-nc-nd/4.0/ )

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据