期刊
CLINICAL ORAL IMPLANTS RESEARCH
卷 32, 期 6, 页码 672-683出版社
WILEY
DOI: 10.1111/clr.13729
关键词
drilling; implant; osteotomy; temperature; thermal exposure
资金
- Institut Straumann AG
This study found that using novel test drills with a shortened drill sequence resulted in lower maximum temperatures and shorter drill times during osteotomy preparation, leading to higher bone-to-implant contact and improved osseointegration compared to standard drills and conventional protocols.
Objectives Thermal and mechanical stresses during osteotomy preparation can impair implant osseointegration. This study investigated implant osseointegration following the measurement of temperature exposure during osteotomy drilling, varying drill design, sequence, and drill wear. Materials and methods 36 tapered implants were placed in a mandibular minipig model after guided drilling of implant osteotomies using 4 different groups: (1) control drills with a conservative, sequential drilling sequence, (2) control drills using a shortened drill sequence (PF), (3) novel test drill displaying an optimized drill design and surface treatment, PF, and (4) aged test drill, PF. Intraosseous temperatures during drilling were measured using a temperature probe. BIC, fBIC, and tissue reactions were histomorphometrically derived after 2 and 8 weeks of healing. Results Compared to control drills (1) or (2), test drills (3) resulted in significantly lower maximum temperatures ((35.4 (CI 30.2-40.5)degrees C vs. (46.5 (CI 41.0-52.0)degrees C, p = .0021)) and shorter drill times ((4.5 (CI 1.6-7.3)sec vs. 10.3 (7.3-13.4)sec). Lower osteotomy temperature values and shorter drill times corroborated with significantly higher BIC after 2 and 8 weeks healing for the test (3) compared to control groups (2) (2 weeks: (44.9 (CI 34.1-55. 7)% vs. (31.3 (CI 20.5-42.2)%, p = <.0001 and 8 weeks: (73.7 ( CI 64.2-83.2)% vs. (66.2 (CI 57.0-75.4)%, p = <.0455). Conclusion The improved osseointegration of implants placed after osteotomy preparation with novel test drills using a shortened drill sequence compared to standard drills and conventional drill protocols might be attributed to more favorable thermal profiles and less mechanical stress exerted on the bone surrounding the implant osteotomy.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据