Multicenter evaluation of the Panbio™ COVID-19 rapid antigen-detection test for the diagnosis of SARS-CoV-2 infection

期刊

CLINICAL MICROBIOLOGY AND INFECTION
卷 27, 期 5, 页码 758-761

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.cmi.2021.02.001

关键词

Antigen diagnosis; Control of cases; COVID-19; Multicentre evaluation; Pandemic; Quick diagnosis; SARS-CoV2

向作者/读者索取更多资源

The study aimed to evaluate the performance of the PanbioRT COVID-19 Ag Rapid Test Device in detecting SARS-CoV-2 in patients with COVID-19 symptoms. The results showed that PanbioRT performed well clinically, especially for patients with a shorter clinical course or a higher viral load.
Objectives: The standard RT-PCR assay for coronavirus disease 2019 (COVID-19) is laborious and time-consuming, limiting testing availability. Rapid antigen-detection tests are faster and less expensive; however, the reliability of these tests must be validated before they can be used widely. The objective of this study was to determine the performance of the Panbio (TM) COVID-19 Ag Rapid Test Device (PanbioRT) (Abbott) in detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in nasopharyngeal swab specimens. Methods: This prospective multicentre study was carried out in ten Spanish university hospitals and included individuals with clinical symptoms or epidemiological criteria of COVID-19. Only individuals with similar to 7 days from the onset of symptoms or from exposure to a confirmed case of COVID-19 were included. Two nasopharyngeal samples were taken to perform the PanbioRT as a point-of-care test and a diagnostic RT-PCR test. Results: Among the 958 patients studied, 325 (90.5%) had true-positive results. The overall sensitivity and specificity for the PanbioRT were 90.5% (95%CI 87.5-93.6) and 98.8% (95%CI 98-99.7), respectively. Sensitivity in participants who had a threshold cycle (C-T) < 25 for the RT-PCR test was 99.5% (95%CI 98.4-100), and in participants with <= 5 days of the clinical course it was 91.8% (95%CI 88.8-94.8). Agreement between techniques was 95.7% (kappa score 0.90; 95%CI 0.88-0.93). Conclusions: The PanbioRT performs well clinically, with even more reliable results for patients with a shorter clinical course of the disease or a higher viral load. The results must be interpreted based on the local epidemiological context. (C) 2021 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据