4.7 Article

Chemical Characterization and Quantification of Circulating Intact PTH and PTH Fragments by High-Resolution Mass Spectrometry in Chronic Renal Failure

期刊

CLINICAL CHEMISTRY
卷 67, 期 6, 页码 843-853

出版社

OXFORD UNIV PRESS INC
DOI: 10.1093/clinchem/hvab013

关键词

-

资金

  1. Fred C. and Katherine B. Andersen Foundation
  2. NIH [5R01DK107870, DK125252]
  3. Centers for Disease Control and Prevention

向作者/读者索取更多资源

The LC-HRMS method identified full-length PTH1-84 and 8 PTH fragments in patients with progressive renal failure, showing significant increase as eGFR declined. PTH concentrations measured using LC-HRMS tended to be lower than those measured using an iPTH immunoassay, particularly in severe chronic renal failure. Circulating PTH7-84 and oxidized forms of PTH1-84 were not detected.
BACKGROUND: The precise concentrations of full-length parathyroid hormone (PTH1-84) and the identity and concentrations of PTH fragments in patients with various stages of chronic renal failure are unknown. METHODS: We developed a liquid chromatography-high resolution mass spectrometry (LC-HRMS) method to characterize and quantify PTH1-84 and PTH fragments in serum of 221 patients with progressive renal dysfunction. Following capture by matrix-bound amino-terminal or carboxyl-terminal region-specific antibodies and elution from matrix, PTH1-84 and PTH fragments were identified and quantitated using LC-HRMS. PTH was simultaneously measured using an intact PTH (iPTH) immunoassay. RESULTS: Full-length PTH1-84 and 8 PTH fragments (PTH28-84, 34-77, 34-84, 37-77, 37-84, 38-77, 38-84, and 45-84) were unequivocally identified and were shown to increase significantly when an eGFR declined to <= 17-23mL/min/1.73m(2). Serum concentrations of PTH1-84 were similar when measured by LC-HRMS following capture by amino-terminal or carboxyl-terminal immunocapture methods. In patients with an eGFR of <30mL/min/1.73 m(2), serum PTH concentrations measured using LC-HRMS were significantly lower than PTH measured using an iPTH immunoassay. PTH7-84 and oxidized forms of PTH1-84 were below the limit of detection (30 and 50pg/mL, respectively). CONCLUSIONS: LC-HRMS identifies circulating PTH1-84, carboxyl-terminal PTH fragments, and mid-region PTH fragments, in patients with progressive renal failure. Serum PTH1-84 and its fragments markedly rise when an eGFR decreases to <= 17-23mL/min/1.73 m(2). PTH concentrations measured using LC-HRMS tend to be lower than those measured using an iPTH immunoassay, particularly in severe chronic renal failure. Our data do not support the existence of circulating PTH7-84 and oxidized PTH1-84.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据