4.7 Article

Ultrasound-assisted gas-liquid mass transfer process in microreactors: The influence of surfactant, channel size and ultrasound frequency

期刊

CHEMICAL ENGINEERING JOURNAL
卷 405, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.cej.2020.126720

关键词

Microchannel; Microfluidics; Acoustic cavitation; Multi-phase hydrodynamics; Flow chemistry; Process intensification

资金

  1. National Natural Science Foundation of China [91634204, 21991103, U1608221]

向作者/读者索取更多资源

The study focuses on the impact of ultrasound on gas-liquid Taylor flow in ultrasonic microreactors, showing that bubble oscillation and mass transfer behavior are influenced by both frequency and channel dimensions. Bubble oscillation amplitude decreases with smaller channel dimensions, and more significant mass transfer enhancement is observed at lower frequencies. The addition of surfactant can further increase the mass transfer effect.
Ultrasound effect on the hydrodynamics and mass transfer behavior of gas-liquid Taylor flow is studied in ultrasonic microreactors with different frequencies (20, 28, 40 kHz) and channel dimensions (0.5 x 0.5, 1.0 x 1.0, 1.5 x 1.5, 2.0 x 2.0 mm(2)). Upon ultrasound irradiation, intense bubble oscillation is excited on the slug bubble, accompanied by cavitation microstreaming vortices around it. The amplitude of bubble oscillation decreases with the decrease of channel dimension as a result of the confinement effect. Channel dimension of 1.0 x 1.0 mm(2) is considered as the critical dimension above which the confinement effect would be eliminated. More intensive bubble oscillation and cavitation microstreaming are observed at lower ultrasound frequency, where more significant mass transfer enhancement is also observed. At frequency of 20 kHz, the overall volumetric mass transfer coefficient is improved by 22 times at the power density of 0.14 W/mL. Adding surfactant (SDS) in the liquid increases the amplitude of bubble oscillation due to the decrease of interfacial tension. Such an increase in the oscillation amplitude enlarges the specific surface area, leading to an increase in the overall volumetric mass transfer coefficient with the increase of surfactant concentration. The detailed effect that how gas-liquid mass transfer would be enhanced by ultrasound is quantified by a mass transfer model, which could predict both the liquid side mass transfer coefficient and the specific surface area satisfactorily.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据