4.7 Article

Assessing ventilation cavity design impact on the energy performance of rainscreen wall assemblies: A CFD study

期刊

BUILDING AND ENVIRONMENT
卷 196, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2021.107789

关键词

Natural convection; Rainscreen; CFD; Energy efficiency; Turbulence

资金

  1. Natural Sciences and Engineering Research Council of Canada (NSERC), Canada Research Chair
  2. School of Construction and the Environment at the British Columbia Institute of Technology (BCIT)

向作者/读者索取更多资源

The impact of ventilation cavity design on the energy performance of rainscreen wall assembly was investigated numerically in CFD, considering various parameters such as cladding material type, sheathing membrane emissivity coefficient, ventilated cavity height, and air gap width. The CFD model was validated with experimental data and simulations were performed for both hot and cold days. Different design alternatives were compared based on heat flux through the wall assembly, showing that certain ventilated cavity constructs can minimize heat loss on cold days and heat gain on hot days.
The impact of the ventilation cavity design on the energy performance of the rainscreen wall assembly was numerically investigated in CFD. The ventilated cavity design parameters considered were the cladding material type (i.e. Fibre cement, brick, and metal cladding), the sheathing membrane emissivity coefficient (i.e. 0.1?0.9), the ventilated cavity height (i.e. 1H and 2H) and the air gap width (i.e. 13 mm?50 mm). The CFD model was validated with experimental data and a dynamic simulation for a typical hot day and cold day is performed for a timestep interval of 5 min. The heat flux through the wall assembly was compared amongst the design alternatives. For the range of parameters considered, the ventilated cavity construct with brick cladding, sheathing membrane emissivity of 0.1, one-storey ventilated cavity, and 13 mm air gap width minimized the heat loss for a typical cold day. However, ventilated cavity construct with brick cladding, sheathing membrane emissivity of 0.1, one-storey ventilated cavity, and 50 mm air gap width minimized the heat gain for a typical hot day.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据