4.7 Article

Design and in-field testing of a multi-level system for continuous subjective occupant feedback on indoor climate

期刊

BUILDING AND ENVIRONMENT
卷 189, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2020.107535

关键词

Occupant satisfaction voting systems; Polling station; Subjective feedback; Thermal comfort; Field tests

资金

  1. Research Council of Norway, within the project Methods for real-time user involvement of indoor climate in smart buildings [277048]
  2. Research Council of Norway
  3. Skanska Norway
  4. KnowIt
  5. Avantor
  6. Asplan Viak
  7. Norwegian University of Science and Technology

向作者/读者索取更多资源

Information gaps between buildings and occupants can result in sub-optimal performance, but new technologies can enhance interaction. Continuous subjective feedback from occupants is valuable for improving building operation and design. Our study found that feedback through CSOF systems can improve user satisfaction and operational efficiency.
Information gaps between the building and the occupant often lead to sub-optimal building performance, impairing the efforts towards more sustainable buildings. New information and communication technology creates new possibilities to reduce this gap, enhancing the interaction between occupants and their environments while providing operational usage data. Continuous subjective feedback from occupants can be used directly to improve building operation and tuning, but may also inform building design and research applications. In this study, we perform a literature study of existing systems for continuous subjective occupant feedback (CSOF) regarding indoor climate. Based on our findings we design a multi-level CSOF system which gathers occupant feedback regarding complaints, control actions and satisfaction evaluations. We qualitatively evaluate the systems in field tests in three buildings with a total of 63 un-informed occupants for a total of 167 days, and identify a series of practical lessons learned. Occupant opinions were collected through regular surveys and a final focus group interview. Deliberate temperature interventions were performed in two of the buildings. The experiments collected a total of 56 complaints, 133 control actions via smartphone, 1344 control actions via manual control and 311 satisfaction evaluations. The occupants provided useful data to the system through their daily interaction with it. They expressed satisfaction with the increased level of interaction and control they were offered through the system and showed a preference for solutions that give an immediate feedback to their actions and have a simple and intuitive interface.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据