The role of contrast-enhanced ultrasound in the diagnosis of malignant non-mass breast lesions and exploration of diagnostic criteria

期刊

BRITISH JOURNAL OF RADIOLOGY
卷 94, 期 1120, 页码 -

出版社

BRITISH INST RADIOLOGY
DOI: 10.1259/bjr.20200880

关键词

-

资金

  1. National Natural Science Foundation of China [82071931]
  2. program for Shanghai Outstanding Medical Academic Leaders [2019LJ18]
  3. interdisciplinary program of Shanghai Jiaotong university [ZH2018ZDA17]
  4. Science and Technology Commission of Shanghai Municipality [20Y11912400]

向作者/读者索取更多资源

This study confirmed the high specificity of CEUS in diagnosing malignant non-mass breast lesions based on diagnostic criteria including enhancement degree, enhancement area, and radial or penetrating vessels. The combination of CEUS with BI-RADS-US is an effective diagnostic tool with both high sensitivity and specificity for the diagnosis of malignant non-mass breast lesions.
Objectives: To assess the value of contrast-enhanced ultrasound (CEUS) for diagnosing malignant non-mass breast lesions (NMLs) and to explore the CEUS diagnostic criteria. Methods: A total of 116 patients with 119 NMLs detected by conventional US were enrolled. Histopathological results were used as the reference standard. The enhancement characteristics of NMLs in CEUS were compared between malignant and benign NMLs. The CEUS diagnostic criteria for malignant NMLs were established using independent diagnostic indicators identified by binary logistic regression analysis. The diagnostic performance of Breast Imaging Reporting and Data System-US (BI-RADS-US), CEUS, and BI-RADS-US combined with CEUS was evaluated and compared. Results: Histopathological results showed 63 and 56 benign and malignant NMLs. Enhancement degree (OR = 5.75, p = 0.003), enhancement area (OR = 4.25, p = 0.005), and radial or penetrating vessels (OR = 7.54, p = 0.003) were independent diagnostic indicators included to establish the CEUS diagnostic criteria. The sensitivity and specificity of BI-RADS-US, CEUS, and BI-RADS-US combined with CEUS were 100 and 30.2%, 80.4 and 74.6%, and 94.6 and 77.8%, respectively; the corresponding areas under the receiver operating characteristic curve (AUC) were 0.819, 0.775, and 0.885, respectively. Conclusions: CEUS has a high specificity in malignant NML diagnosis based on the diagnostic criteria including enhancement degree, enhancement area, and radial or penetrating vessels, but with lower sensitivity than BI-RADS-US. The combination of CEUS and BI-RADS-US is an effective diagnostic tool with both high sensitivity and specificity for the diagnosis of malignant NMLs. Advances in knowledge: In this study, we assessed the diagnostic value of CEUS for malignant NMLs and constructed a feasible diagnostic criterion. We further revealed that the combination of CEUS and BI-RADS-US has a high diagnostic value for malignant NMLs.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据