4.5 Article

Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study

期刊

BMC MUSCULOSKELETAL DISORDERS
卷 22, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12891-020-03918-7

关键词

Supraspinatus tendon; Cadaver; CRet; Shoulder; Glenohumeral capsule; Physical therapy

向作者/读者索取更多资源

In this in vitro study, variations in temperature and current flow in shoulder tissues were evaluated during applications of capacitive-resistive electric transfer therapy. The results showed significant differences in superficial temperature changes, with high-power resistive application leading to the greatest temperature increase. However, the effects on supraspinatus tendon and glenohumeral capsule tissues were not statistically significant, suggesting that the application location and power level may impact superficial temperature but not deeper tissue temperatures.
BackgroundImpingement syndrome is currently estimated to represent 60% of all shoulder pain disorders. Capacitive-Resistive electric transfer therapy is aimed to provoke temperature and current flow changes in superficial and deep tissues. This in vitro study has evaluated the variation of temperature and current flow in the shoulder tissues during two different areas of application of the movable capacitive-resistive electric transfer electrode.MethodsA cross-sectional study designed, five fresh cryopreserved cadavers (10 shoulders) were included in this study. Four interventions (capacitive and resistive modes; low- and high-power) were performed for 5min each by a diathermy T-Plus device in two shoulder regions: postero-superior and antero-lateral. Supraspinatus tendon, glenohumeral capsule and superficial temperatures were recorded at 1-min intervals and 5min after treatment.ResultsA statistically significant difference was found only for the superficial area and time interaction, with high power-resistive application at the postero-superior shoulder area (P<0.035). All the applications showed a 5min after treatment temperature increase compared with the basal data, in all the application points. Superficial temperature in the high power-resistive application showed the greatest percent increase (42.93% 22.58), followed by the temperature in the tendon area with the same high power-resistive application (22.97% 14.70). The high power-resistive application showed the greatest percent of temperature increase in the applications, reaching 65.9% +/- 22.96 at 5-min at the superficial level, and 32% +/- 24.25 at 4-min at the level of the supraspinatus tendon. At the capsule level, high power-resistive was also the application that showed the greatest percent of increase, with 21.52% +/- 16.16. The application with the lowest percent of temperature increase was the low power-capacitive, with a mean value of 4.86% at supraspinatus tendon level and 7.47% at capsular level.ConclusionThe shoulder postero-superior or antero-lateral areas of application of capacitive-resistive electric transfer did not cause statistically significant differences in the temperature changes in either supraspinatus tendon or glenohumeral capsule tissues in cadaveric samples. The high power-resistive application in the postero-superior area significantly increased superficial temperature compared with the same application in the antero-lateral position area.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据