4.8 Article

Strategic design and improvement of the internal electron transfer of heme b domain-fused glucose dehydrogenase for use in direct electron transfer-type glucose sensors

期刊

BIOSENSORS & BIOELECTRONICS
卷 176, 期 -, 页码 -

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2020.112911

关键词

Glucose dehydrogenase; Surface electrostatics; Direct electron transfer; Fusion protein; Docking simulation

向作者/读者索取更多资源

Redesigned mutant Pcyb-AfGDH enzymes exhibit faster intramolecular electron transfer rates and higher DET current values, showing potential for application in continuous glucose monitoring systems.
A fusion enzyme composed of an Aspergillus flavus-derived flavin adenine dinucleotide glucose dehydrogenase (AfGDH) and an electron transfer domain of Phanerochaete chrysosporium-derived cellobiose dehydrogenase (Pcyb) was previously reported to show the direct electron transfer (DET) ability to an electrode. However, its slow intramolecular electron transfer (IET) rate from the FAD to the heme, limited the sensor signals. In this study, fusion FADGDH (Pcyb-AfGDH) enzymes were strategically redesigned by performing docking simulation, following surface-electrostatic potential estimation in the predicted area. Based on these predictions, we selected the amino acid substitution on Glu324, or on Asn408 to Lys to increase the positive charge at the rim of the interdomain region. Pcyb-AfGDH mutants were recombinantly produced using Pichia pastoris as the host microorganism, and their IET was evaluated. Spectroscopic observations showed that the Glu324Lys (E324K) and Asn408Lys (N408K) Pcyb-AfGDH mutants showed approximately 1.70and 9.0-fold faster IET than that of wildtype Pcyb-AfGDH, respectively. Electrochemical evaluation revealed that the mutant Pcyb-AfGDHimmobilized electrodes showed higher DET current values than that of the wildtype Pcyb-AfGDH-immobilized electrodes at pH 6.5, which was approximately 9-fold higher in the E324K mutant and 15-fold higher in the N408K mutant, than in the wildtype. Glucose enzyme sensors employing N408K mutant was able to measure glucose concentration under physiological condition using artificial interstitial fluid at pH 7.4, whereas the one with wildtype Pcyb-AfGDH was not. These results indicated that the sensor employed the redesigned mutant Pcyb-AfGDH can be used for future continuous glucose monitoring system based on direct electron transfer principle. (247 words).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据