4.7 Article

Multi-objective optimization of a combined cooling, heating, and power system with subcooled compressed air energy storage considering off-design characteristics

期刊

APPLIED THERMAL ENGINEERING
卷 187, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2021.116562

关键词

Subcooled compressed air energy storage; Off-design operation; Multi-objective optimization; Multi-vector energy systems

资金

  1. National Fundamental Research Program of China 973 project [2014CB249201]

向作者/读者索取更多资源

The performance of a combined cooling, heating, and power system under dynamic operation conditions was studied by considering real wind fluctuation data and off-design performance characteristics, and using a bi-level differential evolution algorithm for multi-objective optimization. The results indicate that the off-design characteristics significantly affect the trigeneration performance, with the storage system showing advantages in the transition season.
In this work, the performance of a combined cooling, heating, and power system is studied under dynamic operation conditions. The hybrid system consists of a wind farm and a subcooled compressed air energy storage system, providing energy for an integrated energy network including established heating, cooling, and electricity grids. For the presented system, real wind fluctuation data and the off-design performance characteristics of each component are considered. The efficiency of the integrated cooling, heating and power system and the cost of the system are taken into account as the objectives of the problem to optimize. Then, a bi-level differential evolution algorithm is proposed to handle the multi-objective optimization of the system. Different solutions are carried out and compared to investigate the trigeneration of the system under various energy demand conditions. The results show that the off-design characteristics have a significant side-effect on the trigeneration performance of the system. The storage system has more obvious advantages in the transition season, as the states of charge of the system are 82%, 84% and 92% in winter, summer and transition seasons, respectively. The application of the system can effectively avoid the negative effect of the off-design characteristics of equipment and has great potential for energy supply in combined cooling, heating, and power systems.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据