4.5 Article

Improvement of a computer-aided alignment algorithm for the nonsymmetric off-axis reflective telescope

期刊

APPLIED OPTICS
卷 60, 期 8, 页码 2127-2140

出版社

OPTICAL SOC AMER
DOI: 10.1364/AO.413533

关键词

-

类别

资金

  1. National Natural Science Foundation of China [61875190, 12003033]

向作者/读者索取更多资源

This research analyzes the alignment sensitivity of each component in the optical path of an off-axis TMA telescope and proposes an adaptive damping factor least-squares algorithm model to improve efficiency. Experimental verification shows that the method can reduce initial alignment accuracy requirements and improve adaptability to Zernike coefficient measurement noise, resulting in enhanced wave aberration values.
Due to complications of the off-axis three-mirror anastigmat (TMA) telescope, each optical element in the offaxis TMA telescope is introduced with theoretical eccentricity and tilt. Moreover, the introduction of freeform surfaces and other optical elements with complex surface features generally causes the initial alignment accuracy of the optical path to be low. A large initial alignment error amplifies the sensitivity of the misalignment calculation accuracy to the measurement error of the Zernike coefficient, resulting in difficulty obtaining convergence results for a computer-aided alignment algorithm. Considering the above issues, the alignment sensitivity of each component in the optical path is analyzed in this. The large conditional number of the sensitivity matrix results in poor algorithm robustness. Thus, an adaptive damping factor least-squares algorithm model is proposed and derived to improve the efficiency of the classical least-squares algorithm. A method for piecewise optimization of the damping factor is also deduced. Experiments based on a 0.6 m off-axis TMA telescope verify the effectiveness of the algorithm. Simulation and integration experiments show that the proposed method can reduce the accuracy requirements of the initial alignment and improve the adaptability of Zernike coefficient measurement noise. The alignment procedure is carried out for three iterations, and the average of the five field-of-view wave aberration values is enhanced from 2.1 lambda (RMS; lambda = 632.8 nm) to 0.09 lambda (average). The improved algorithm can solve the large initial alignment error of a nonsymmetrical off-axis reflective optical system with a freeform surface as well as the problem of the low success rate of the misalignment value due to low Zernike coefficient measurement accuracy. (C) 2021 Optical Society of America

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据