4.8 Article

Two-level hierarchical model predictive control with an optimised cost function for energy management in building microgrids

期刊

APPLIED ENERGY
卷 285, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2020.116420

关键词

Hierarchical model predictive control; Hydrogen storage system; Li-ion batteries; Data-driven algorithms; Economic optimisation

资金

  1. New Aquitaine Region [AAPFO424953]
  2. ESTIA, the Institute of Advanced Industrial Technologies

向作者/读者索取更多资源

Hybrid energy storage systems, combining long-term and short-term energy storage, can enhance building microgrid capacity and shift demand peaks, increasing self-consumption rate. This study proposes a two-level Hierarchical Model Predictive Controller enhanced by data-driven modules to improve building microgrid performance, reducing costs and energy storage device degradation.
Hybrid energy storage systems have been increasingly envisaged for building microgrids to soften the drawbacks arising from the unpredictability of renewable energy resources and dwelling occupancy. The combination of longand shortterm energy storage systems can enhance the building microgrid capacity of shifting the demand peak toward periods of power generation, increasing the marks of self-consumption rate. However, the design of energy management systems for hybrid energy storage microgrids is more complex than single ones due to a greater number possible solutions. Faced with this issue, this paper proposes a two-level Hierarchical Model Predictive Controller (HMPC) enhanced by two data driven modules to improve the performance of building microgrids equipped with hybrid energy storage continuously and automatically. With minimum pre-design steps, the two data-driven algorithms improve the accuracy of Li-ion batteries and hydrogen storage models and determine adequate parameters for the HMPC cost function. Relying predominantly on data measurements, the proposed hierarchical controller determines which energy storage device must be run on a daily basis based on the estimation of the annual self-consumption rate and the annual microgrid operation costs. This real-time analysis decreases microgrid expenditure because it avoids grid penalisation regarding the energy autonomy index and reduces the degradation and maintenance of energy storage devices. Compared to a standard rule based strategy, the proposed controller reduces annual costs up to 5% in residential buildings and 9% in non-residential ones. In contrast, compared to a conventional HMPC the annual expenditure is reduced from 1% to 7% in both types of buildings.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据