4.5 Article

An investigation of pressure build-up effects due to check valve's closing characteristics using dynamic mesh techniques of CFD

期刊

ANNALS OF NUCLEAR ENERGY
卷 152, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.anucene.2020.107996

关键词

Check valve; Computational fluid dynamics; Dynamic mesh

资金

  1. Nuclear Safety Research Program through the Korea Foundation Of Nuclear Safety (KoFONS)
  2. Nuclear Safety and Security Commission (NSSC) of the Republic of Korea [1805007]

向作者/读者索取更多资源

This study compared four different moving mesh techniques of CFD and found that these techniques can well describe the dynamic behavior of a swing check valve during closure, but there are differences in predicting the inflowing fluid velocity when the valve is fully closed.
The present study provides recommendations for choosing the appropriate moving mesh techniques of CFD to describe the dynamic behavior of a check valve and to evaluate a pressure build-up in response to the valve's closing behavior. Four different moving mesh techniques of CFD were modeled and compared, and the compressibility of the fluid was involved in simulating the pressure build-up by valve closing. The results showed that the swing check valve's dynamic behavior during the valve closure could be well described by the moving mesh techniques presented in this study because the velocity profiles at the outlet of each method were similar until the valve was almost closed. However, even though the moving mesh techniques described the check valve's closing behavior well, the predictions of the inflowing fluid velocity at the moment when the valve was fully closed were different from one another. (C) 2020 Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据