4.8 Article

LICAR: An Application for Isotopic Correction of Targeted Lipidomic Data Acquired with Class-Based Chromatographic Separations Using Multiple Reaction Monitoring

期刊

ANALYTICAL CHEMISTRY
卷 93, 期 6, 页码 3163-3171

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.0c04565

关键词

-

资金

  1. National Research Foundation (SIS grant) [NRF2017_SISFP08]
  2. National University of Singapore via the Life Sciences Institute
  3. A*STAR [IAF-ICP I1901E0040]

向作者/读者索取更多资源

Lipidomics is an important field in biomedical and clinical research, requiring reliable quantification of lipid species. Different chromatography techniques are used in lipidomics, and isotopic correction is essential for accurate quantitation.
Lipidomics is developing as an important area in biomedical and clinical research. Reliable quantification of lipid species is required for clinical translation of lipidomic studies. Hydrophilic interaction chromatography (HILIC), normal-phase liquid chromatography (NPLC), and supercritical fluid chromatography (SFC) are commonly used techniques in lipidomics and provide class-based separation of lipids. While co-elution of lipid species and their internal standards is an advantage for accurate quantification, it leads to isotopic overlap between species of the same lipid class. In shotgun lipidomics, isotopic correction is typically done based on elemental formulas of precursor ions. In multiple reaction monitoring (MRM) analyses, however, this approach should not be used, as the overall contribution of heavy isotopes to the MRM transitions' intensities depends on their location in the molecule with respect to the fragmentation pattern. We present an algorithm, provided in the R programming language, for isotopic correction in class-based separation using MRM, extracting relevant structural information from MRM transitions to apply adequate isotopic correction factors. Using standards, we show that our algorithm accurately estimates the isotopic contribution of isotopologues to MRM transitions' measured intensities. Using human plasma as an example, we demonstrate the necessity of adequate isotopic correction for accurate quantitation of lipids measured by MRM with class-based chromatographic separation. We show that over a third of the measured phosphatidylcholine species had their intensity corrected by more than 10%. This isotopic correction algorithm and R-implemented application enable a more accurate quantification of lipids in class-based separation-MRM, a prerequisite for successful translation of lipidomic applications.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据