4.7 Article

A syringe-aided apta-nanosensing method for colorimetric determination of acetamiprid

期刊

ANALYTICA CHIMICA ACTA
卷 1150, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.aca.2020.11.050

关键词

Aptamer; Nanosensors; Syringe; Colorimetric; Acetamiprid

资金

  1. National Natural Science Foundation of China [31871878]
  2. Natural Science Foundation of Shandong Province, China [ZR2018BCE057]
  3. Key R&D Project of Shandong Province [2018GSF118032]
  4. China University of Petroleum (East China) Students' Innovation and Entrepreneurship Training Program [20190164]

向作者/读者索取更多资源

A syringe-aided apta-nanosensing method for colorimetric determination of acetamiprid is reported. The method allows for sensitive detection of acetamiprid concentration visible to the naked eye, with quantitative analysis achieved through spectrometer measurements.
A syringe-aided apta-nanosensing method is reported for the colorimetric determination of acetamiprid. The method employs double-stranded (ds) DNA-conjugated gold nanoparticle@magnetic agarose beads, i.e., dsDNA-AuNP@MABs as peroxidase-mimicking composite probes, in which the aptamer is indirectly attached to the AuNP surface through its hybridization with complementary DNA (cDNA). Upon contact with the acetamiprid target, the probes can give perceptible color change due to the possible conformation switch from dsDNA's brush-like to cDNA's 'pancake' regime. An air-spaced pumping procedure using a syringe equipped with ring magnets as the operation platform was proposed to facilitate the magnetic separation of the sensing probes. Therefore, the analytical steps can be easily accomplished in a syringe, including probe loading, acetamiprid capture and magnetic separation from crude samples, chromogenic reagent loading and colorimetric visualization. Acetamiprid concentration down to 3.3 ppb can be easily identified by the naked eye. The final solution also can be transferred for quantitative measurement. Under spectrometer, the ratio of the absorbance at 652 nm in the presence and absence of acetamiprid (A/A(0)) is linearly related to the acetamiprid concentration in the 0.4-4.5 ppb range. The limit of detection is calculated to be 0.24 ppb. Moreover, satisfactory recoveries ranging from 90.90 to 91.82% with relative standard deviations of <= 2.96% were obtained in analyzing real spiked samples. (C) 2020 Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据