Simple paper-based colorimetric and fluorescent glucose sensor using N-doped carbon dots and metal oxide hybrid structures

期刊

ANALYTICA CHIMICA ACTA
卷 1147, 期 -, 页码 187-198

出版社

ELSEVIER
DOI: 10.1016/j.aca.2020.11.023

关键词

Fluorescence; Colorimetric; Carbon dots; Mimetic catalyst; Paper-sensor device

资金

  1. Basic Science Research Program through the National Research Foundation of Korea (NRF) - Ministry of Science, ICT and Future Planning [2019R1A2B5B02069683]

向作者/读者索取更多资源

A new strategy for sensing hydrogen peroxide (H2O2) and glucose using metal oxide-carbon dot hybrid structure was investigated. The sensing system showed high accuracy in detecting H2O2 and glucose and could be applied for on-site analysis of glucose without the use of a spectrometer.
A new strategy for the fluorescent and colorimetric sensing of hydrogen peroxide (H2O2) and glucose based on the metal oxide - carbon-dot hybrid structure was investigated. The sensing system is related to the catalytic oxidation reaction of glucose-by-glucose oxidase (GOx) to H2O2. In this study, a metal oxide hybrid with nitrogen-doped carbon dots (MFNCDs) that showed intrinsic peroxidase-like activity was synthesized and used as a catalyst instead of GOx to oxidize 3,3',5,5'-tetramethylbenzidine (TMB) to blue-emitting oxidized TMB (oxTMB) in the presence of hydrogen peroxide (H2O2). The fluorescence of MFNCDs/TMB at 405 nm was quenched in the presence of H2O2 through the inner filter effect (IFE) and electron transfer within MFNCDs, oxTMB, and glucose system. Therefore, the fluorescence and absorbance intensity can be applied to the quantitative determination of the concentration of H2O2 and glucose with a wide linear range. The detection limit for H2O2 and glucose based on the colorimetric method were as low as 84 nM and 0.41 mu M, respectively. In contrast, the detection limit for H2O2 and glucose based on the fluorescent method were as low as 97 nM and 0.85 mu M, respectively. Furthermore, the colorimetric readout on the paper device based on the changing color of the solution could also be integrated with a smartphone platform to conduct the on-site analysis of glucose without the use of the spectrometer. In addition, this dual sensor can be applied to detect glucose in real serum with highly accurate results, making it a good candidate for biosensor applications. (C) 2020 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据