4.6 Article

Assessment of Subsampling Strategies in Microspectroscopy of Environmental Microplastic Samples

期刊

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fenvs.2020.579676

关键词

microplastics; subsampling; microspectroscopy; Raman; Fourier-Transform infrared

资金

  1. Federal Ministry of Education and Research (BMBF Germany) [03F0788A, 02WPL1446 I, 03F0789A]
  2. European Union [03F0775A]
  3. BMBF [03F0775A]

向作者/读者索取更多资源

Analyzing the environmental occurrence of MP particles has received significant attention in the past decade, with a focus on effective risk assessment through accurate sampling and analysis methods. The choice of subsampling methods is crucial for reducing MP particle count errors, and increasing the fraction of MP particles in samples can help achieve lower errors.
The analysis of environmental occurrence of microplastic (MP) particles has gained notable attention within the past decade. An effective risk assessment of MP litter requires elucidating sources of MP particles, their pathways of distribution and, ultimately, sinks. Therefore, sampling has to be done in high frequency, both spatially and temporally, resulting in a high number of samples to analyze. Microspectroscopy techniques, such as FTIR imaging or Raman particle measurements allow an accurate analysis of MP particles regarding their chemical classification and size. However, these methods are time-consuming, which gives motivation to establish subsampling protocols that require measuring less particles, while still obtaining reliable results. The challenge regarding the subsampling of environmental MP samples lies in the heterogeneity of MP types and the relatively low numbers of target particles. Herein, we present a comprehensive assessment of different proposed subsampling methods on a selection of real-world samples from different environmental compartments. The methods are analyzed and compared with respect to resulting MP count errors, which eventually allows giving recommendations for staying within acceptable error margins. Our results are based on measurements with Raman microspectroscopy, but are applicable to any other analysis technique. We show that the subsampling-errors are mainly due to statistical counting errors (i.e., extrapolation from low numbers) and only in edge cases additionally impacted by inhomogeneous distribution of particles on the filters. Keeping the subsampling-errors low can mainly be realized by increasing the fraction of MP particles in the samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据