4.6 Article

Electrochemical behavior of the cotinine at a boron-doped diamond electrode and its determination in saliva by multiple-pulse amperometry in an FIA system

期刊

ELECTROCHIMICA ACTA
卷 222, 期 -, 页码 331-337

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.electacta.2016.10.177

关键词

Cotinine; Tobacco; Pulsed Amperometry; FIA; Boron-Doped Diamond

资金

  1. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq-Project) [481683/2013-5]
  2. Fundacao de Amparo a Pesquisa do Estado de Minas Gerais (FAPEMIG)
  3. FAPEMIG [CEX-RED-00010-14]

向作者/读者索取更多资源

Cotinine (CO) is the principal metabolite of nicotine, and it is used as a biomarker to monitor the exposure of an individual to tobacco. This paper sought to present the use of a boron-doped diamond (BDD) electrode for the electrochemical characterization of CO by voltammetric techniques and its quantification in saliva samples by multiple-pulse amperometry (MPA) in a flow injection analysis (FIA) system. In phosphate buffer solution 0.1 mol L-1 (pH 7), the CO presented two electrochemical processes, one anodic at +1.8 V and one cathodic at -1.2 V (vs. Ag/AgCl). The second process was dependent on the first and both processes were irreversible. It was found that CO electrochemical processes are controlled by diffusion and that two-protons and two-electrons are involved in the oxidation reaction. In determination of CO in saliva samples, the MPA detection was used, applying four potential pulses: (1) at +1.8 V/400 ms, generator potential pulse for oxidation of CO; (2) at -1.0 V/500 ms, potential pulse for remove possible interferents; (3) at -1.2 V/30 ms, collector potential pulse for reduction of the product generated and CO quantification; (4) 1.45 V/300 ms, potential pulse for cleaning BDD electrode. The proposed method attained an analytical frequency of 36 determinations per hour with a relative standard deviation of 1.47% for 10 measurements of 1.0 x 10(-5) mol L-1 CO. A good linear range from 0.5 to 100 mu mol L-1 was obtained with a detection limit for CO estimated at 0.06 mu mol L-1. Approximately 100% of the CO added to saliva samples was recovered. Therefore, this work presents, for the first time, the electrochemical behavior of the CO at an electrode as well as a simple, fast and low-cost method for monitoring the degree of exposure to tobacco by CO determination in saliva samples using the FIA-MPA technique. (C) 2016 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据