Simultaneous powdered activated carbon and coagulant injection during ballasted flocculation for trace benzene removal from diesel and gasoline-contaminated surface waters

期刊

出版社

ELSEVIER
DOI: 10.1016/j.jwpe.2020.101846

关键词

Benzene; Ballasted flocculation; Powdered activated carbon (PAC); Drinking water production; Oil spill

资金

  1. City of Montreal, Veolia Water Technologies Canada
  2. City of Laval
  3. City of Repentigny
  4. City of Longueuil
  5. National Science and Engineering Research Council of Canada (NSERC)

向作者/读者索取更多资源

The study found that ballasted flocculation alone is not efficient for benzene removal and the addition of PAC is necessary. Simultaneous addition of PAC and coagulant reduced benzene concentration substantially, but could not meet the Canadian threshold concentration.
Subsequent to an oil spill, conventional physico-chemical treatment processes such as ballasted flocculation would serve as the principal barrier in drinking water treatment plants (DWTP) against contamination from toxic soluble contaminants such as benzene. Benzene is a well-known carcinogenic compound and its maximum threshold concentrations in drinking water are regulated at 5 ?g/L and 0.5 ?g/L in the United States and in Quebec, Canada, respectively. Our study focused on ballasted flocculation in order to determine its removal efficiency for traces of dissolved petroleum hydrocarbons originating from diesel and gasoline contamination. Results show that ballasted flocculation alone, using alum or ferric sulphate as coagulant, is not efficient for benzene reduction below regulations. Addition of an adsorbent such as powdered activated carbon (PAC) is necessary. From PAC adsorption isotherms and kinetics, we found an optimal dose of 80 mg PAC/L and contact times of 15 and 30 min for diesel and gasoline-contaminated waters, respectively. The simultaneous addition of PAC and coagulant during ballasted flocculation showed that although benzene concentration declined substantially, alum treatment could not decrease concentrations below the Canadian threshold (0.5 ?g/L) while the US regulation value was met. Analysis of PAC-ballasted flocculation tests demonstrated the likelihood of PAC pore blockage in the presence of coagulants. Although PAC doses as high as 80 mg PAC/L were introduced during ballasted flocculation, settled water quality was not negatively impacted. Findings from this study will help DWTP in their effort to prepare emergency response plans for the event of an oil spill.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据