4.3 Article

Automated quantification of baseline imaging PET metrics on FDG PET/CT images of pediatric Hodgkin lymphoma patients

期刊

EJNMMI PHYSICS
卷 7, 期 1, 页码 -

出版社

SPRINGER
DOI: 10.1186/s40658-020-00346-3

关键词

Pediatric lymphoma; Convolutional neural networks; Imaging biomarkers; PET

资金

  1. GE Healthcare
  2. National Institutes of Health [U10CA098543, U10CA098413, U10CA180886, U10CA180899, CA29511, U24CA180803]
  3. St. Baldricks Foundation

向作者/读者索取更多资源

Purpose For pediatric lymphoma, quantitative FDG PET/CT imaging features such as metabolic tumor volume (MTV) are important for prognosis and risk stratification strategies. However, feature extraction is difficult and time-consuming in cases of high disease burden. The purpose of this study was to fully automate the measurement of PET imaging features in PET/CT images of pediatric lymphoma. Methods F-18-FDG PET/CT baseline images of 100 pediatric Hodgkin lymphoma patients were retrospectively analyzed. Two nuclear medicine physicians identified and segmented FDG avid disease using PET thresholding methods. Both PET and CT images were used as inputs to a three-dimensional patch-based, multi-resolution pathway convolutional neural network architecture, DeepMedic. The model was trained to replicate physician segmentations using an ensemble of three networks trained with 5-fold cross-validation. The maximum SUV (SUVmax), MTV, total lesion glycolysis (TLG), surface-area-to-volume ratio (SA/MTV), and a measure of disease spread (Dmax(patient)) were extracted from the model output. Pearson's correlation coefficient and relative percent differences were calculated between automated and physician-extracted features. Results Median Dice similarity coefficient of patient contours between automated and physician contours was 0.86 (IQR 0.78-0.91). Automated SUVmax values matched exactly the physician determined values in 81/100 cases, with Pearson's correlation coefficient (R) of 0.95. Automated MTV was strongly correlated with physician MTV (R = 0.88), though it was slightly underestimated with a median (IQR) relative difference of - 4.3% (- 10.0-5.7%). Agreement of TLG was excellent (R = 0.94), with median (IQR) relative difference of - 0.4% (- 5.2-7.0%). Median relative percent differences were 6.8% (R = 0.91; IQR 1.6-4.3%) for SA/MTV, and 4.5% (R = 0.51; IQR - 7.5-40.9%) for Dmax(patient), which was the most difficult feature to quantify automatically. Conclusions An automated method using an ensemble of multi-resolution pathway 3D CNNs was able to quantify PET imaging features of lymphoma on baseline FDG PET/CT images with excellent agreement to reference physician PET segmentation. Automated methods with faster throughput for PET quantitation, such as MTV and TLG, show promise in more accessible clinical and research applications.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据