In a study of 296 patients, the use of a DLR algorithm for cardiac CCTA in an acute stroke imaging protocol significantly reduced radiation dose and improved image quality compared to an iterative reconstruction algorithm.
Background: To assess the radiation dose and image quality of cardiac computed tomography angiography (CCTA) in an acute stroke imaging protocol using a deep learning reconstruction (DLR) method compared to a hybrid iterative reconstruction algorithm. Methods: Retrospective analysis of 296 consecutive patients admitted to the emergency department for stroke suspicion. All patients underwent a stroke CT imaging protocol including a non-enhanced brain CT, a brain perfusion CT imaging if necessary, a CT angiography (CTA) of the supra-aortic vessels, a CCTA and a post-contrast brain CT. The CCTA was performed with a prospectively ECG-gated volume acquisition. Among all CT scans performed, 143 were reconstructed with an iterative reconstruction algorithm (AIDR 3D, adaptive iterative dose reduction three dimensional) and 146 with a DLR algorithm (AiCE, advanced intelligent clear-IQ engine). Image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and subjective image quality (IQ) scored from 1 to 4 were assessed. Dose-length product (DLP), volume CT dose index (CTDIvol) and effective dose (ED) were obtained. Results: The radiation dose was significantly lower with AiCE than with AIDR 3D (DLP =106.450.0 vs. 176.1 +/- 37.1 mGy.cm, CTDIvol =6.9 +/- 3.2 vs. 11.5 +/- 2.2 mGy, and ED =1.5 +/- 0.7 vs. 2.5 +/- 0.5 mSv) (P<0.001). The median SNR and CNR were higher [9.9 (IQR, 8.1-12.3); and 12.6 (IQR, 10.5-15.5), respectively], with AiCE than with AIDR 3D [6.5 (IQR, 5.2-8.5); and 8.4 (IQR, 6.7-11.0), respectively] (P<0.001). SNR and CNR were increased by 51% and 49%, respectively, with AiCE compared to AIDR 3D. The image quality was significantly better with AiCE (mean IQ score =3.4 +/- 0.7) than with AIDR 3D (mean IQ score =3 +/- 0.9) (P<0.001). Conclusions: The use of a DLR algorithm for cardiac CTA in an acute stroke imaging protocol reduced the radiation dose by about 40% and improved the image quality by about 50% compared to an iterative reconstruction algorithm.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据