期刊
CELLS
卷 9, 期 12, 页码 -出版社
MDPI
DOI: 10.3390/cells9122610
关键词
MRI; CEST; pH; muscle
类别
资金
- Ministry of Science and Technology of Taiwan [MOST 108-2113-M-001-025, MOST 109-2113-M-001-010]
- Institute of Biomedical Sciences, Academia Sinica
Magnetic resonance imaging (MRI) is extensively used in clinical and basic biomedical research. However, MRI detection of pH changes still poses a technical challenge. Chemical exchange saturation transfer (CEST) imaging is a possible solution to this problem. Using saturation transfer, alterations in the exchange rates between the solute and water protons because of small pH changes can be detected with greater sensitivity. In this study, we examined a fatigued skeletal muscle model in electrically stimulated mice. The measured CEST signal ratio was between 1.96 ppm and 2.6 ppm in the z-spectrum, and this was associated with pH values based on the ratio between the creatine (Cr) and the phosphocreatine (PCr). The CEST results demonstrated a significant contrast change at the electrical stimulation site. Moreover, the pH value was observed to decrease from 7.23 to 7.15 within 20 h after electrical stimulation. This pH decrease was verified by P-31 magnetic resonance spectroscopy and behavioral tests, which showed a consistent variation over time.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐