4.7 Article

Performance Evaluation of Porous Graphene as Filter Media for the Removal of Pharmaceutical/Emerging Contaminants from Water and Wastewater

期刊

NANOMATERIALS
卷 11, 期 1, 页码 -

出版社

MDPI
DOI: 10.3390/nano11010079

关键词

pharmaceutical contaminants; graphene-based materials; porous graphene; adsorption filters; wastewater treatment

资金

  1. Department of Science and Technology, Government of India [DST/TM/INDO-UK/2K17/66(C)]
  2. UK Natural Environment Research Council under India-UK Water Quality Programme [NE/R003548/1]
  3. NERC [NE/R003548/1] Funding Source: UKRI

向作者/读者索取更多资源

This study reports the successful removal of pharmaceutical contaminants using porous graphene as a filter-based column, evaluating factors such as reactive layer configurations, bed packing heights, and filter sizes. Increasing the dosage and bed height and size of porous graphene improved the removal efficiency of emerging contaminants from water and wastewater.
Graphene and its counterparts have been widely used for the removal of contaminants from (waste)water but with limited success for the removal of pharmaceutical contaminants. Driven by this need, this study reports, for the first time, the removal of pharmaceuticals from real contaminated water samples using porous graphene (PG) as a filter-based column. This work systematically evaluates the performance of PG as a filter medium for the removal of widely consumed pharmaceutical/emerging contaminants (ECs) such as atenolol, carbamazepine, ciprofloxacin, diclofenac, gemfibrozil and ibuprofen. Several factors were investigated in these column studies, including different reactive layer configurations, bed packing heights (5-45 mm), filter sizes (inner diameter 18-40 mm), adsorbent dosages (100-500 mg-PG) and water bodies (distilled water, greywater, and actual effluent wastewater). Sustainable synthesis of PG was carried out followed by its use as a filter medium for the removal of pharmaceuticals at high concentrations (10.5 +/- 0.5 mg/L) and trace concentrations (1 mg/L). These findings revealed that the double-layered PG-sand column outperformed a PG single-layered configuration for the removal of most of the ECs. The removal efficiency of ECs from their solutions was improved by increasing PG dosages and filter bed height and size. Although the treatment of mixed pharmaceutical solutions from different water bodies was affected by the negative interference caused by competing water compounds, the treatment of ECs-contaminated greywater was not severely affected. Our findings suggest that PG, as a highly efficient filter medium, could be used for the removal of emerging pharmaceutical contaminants from water and wastewater.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据