4.6 Article

Optimal concentration of ethylenediaminetetraacetic acid as an irrigation solution additive to reduce infection rates in rat models of contaminated wound

期刊

BONE & JOINT RESEARCH
卷 10, 期 1, 页码 68-76

出版社

BRITISH EDITORIAL SOC BONE & JOINT SURGERY
DOI: 10.1302/2046-3758.101.BJR-2020-0338.R1

关键词

Antibacterial agents; Therapeutic irrigation; Surgical wound infection

资金

  1. National Natural Science Foundation of China [82002324, 81974331, 81672144]
  2. Shanghai Municipal Health Commission [20194Y0254]

向作者/读者索取更多资源

In wound irrigation, EDTA at concentrations below 10 mM is safe for use. The optimal concentration of EDTA-NS varies depending on the type of wound after experimental inoculation of three types of wound models.
Aims In wound irrigation, 1 mM ethylenediaminetetraacetic acid (EDTA) is more efficacious than normal saline (NS) in removing bacteria from a contaminated wound. However, the optimal EDTA concentration remains unknown for different animal wound models. Methods The cell toxicity of different concentrations of EDTA dissolved in NS (EDTA--NS) was assessed by Cell Counting Kit-8 (CCK-8). Various concentrations of EDTA-NS irrigation solution were compared in three female Sprague-Dawley rat models: 1) a skin defect; 2) a bone exposed; and 3) a wound with an intra--articular implant. All three models were contaminated with Staphylococcus aureus or Escherichia coli. EDTA was dissolved at a concentration of 0 (as control), 0.1, 0.5, 1, 2, 5, 10, 50, and 100 mM in sterile NS. Samples were collected from the wounds and cultured. The bacterial culture-positive rate (colony formation) and infection rate (pus formation) of each treatment group were compared after irrigation and debridement. Results Cell viability intervened below 10 mM concentrations of EDTA-NS showed no cytotoxicity. Concentrations of 1, 2, and 5 mM EDTA-NS had lower rates of infection and positive cultures for S. aureus and E. coli compared with other concentrations in the skin defect model. For the bone exposed model, 0.5, 1, and 2 mM EDTA-NS had lower rates of infection and positive cultures. For intra-articular implant models 10 and 50 mM, EDTA-NS had the lowest rates of infection and positive cultures. Conclusion The concentrations of EDTA-NS below 10 mM are safe for irrigation. The optimal concentration of EDTA-NS varies by type of wound after experimental inoculation of three types of wound.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据