4.3 Article

Factors Affecting Implant Stability Quotients at Immediately and Conventionally Loaded Implants in the Posterior Maxilla: A Split-Mouth Randomized Controlled Trial

出版社

WILEY
DOI: 10.1111/jopr.13296

关键词

Immediate loading; maxilla; primary stability; randomized clinical trial; resonance frequency analysis; secondary stability; variable-thread tapered implant; implant

资金

  1. Nobel Biocare Services AG, Kloten, Switzerland [2010-954]

向作者/读者索取更多资源

The study aimed to assess the primary and secondary stability of variable-thread tapered implants in the posterior maxilla, and analyze the impact of various factors on implant stability quotients. The results showed that measurement direction and time are the most significant parameters affecting the stability quotients of these implants in the posterior maxilla.
Purpose: To assess primary and secondary stability of variable-thread tapered implants in the posterior maxilla and analyze the impact of various factors on implant stability quotients (ISQs). Materials and methods: Twenty-six subjects received 3-4 adjacent implants in the maxillary premolar-molar sextants to replace bilateral tooth loss. The implants on one side were immediately loaded with a provisional fixed prosthesis regardless of their primary stability. The contralateral control implants were conventionally loaded. Bone quality was subjectively recorded and primary stability was assessed by means of insertion torque values (ITVs) and ISQs in 4 directions. Secondary stability was measured by ISQ at definitive prosthesis delivery (3-3.5 months postoperatively), and 12 months after definitive loading. The impact of measurement direction, loading protocol, time, site-related (bone quality, implant position, crestal buccal bone thickness, apical cortical anchorage), and implant-related (implant dimensions, abutment height) variables on ISQs was assessed. Results: For logistic reasons, ISQs were obtained for only 18 patients with 60 test and 60 control implants. Most of the implants (82%) at baseline had their lowest ISQ on the buccal aspect. There were no significant differences between ISQs measured in the buccal and palatal directions, or between ISQs in the mesial and distal directions. The mean of buccal and palatal ISQs was significantly lower than the mean of the 2 interproximal measurements at all evaluation periods. ISQs were not significantly different between the 2 loading groups at any time point. All implants showed a time-dependent increase in ISQs. Baseline ISQ correlated weakly with bone quality and ITV. None of the variables had a significant impact on baseline ISQs, except for implants in second molar sites which showed poorer primary stability than first premolars. Conclusion: Measurement direction and time are the most significant parameters affecting ISQs of variable-thread tapered implants in the posterior maxilla.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据