4.7 Article

Dual-quenching electrochemiluminescence system based on novel acceptor CoOOH@Au NPs for early detection of procalcitonin

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 332, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2021.129544

关键词

Electrochemiluminescence; Graphitic carbon nitride; Dual-quenching; Resonance energy transfer; CoOOH

资金

  1. Jinan Scientific Research Leader Workshop Project [2018GXRC024]
  2. National Key Scientific Instrument and Equipment Development Project of China [21627809]
  3. National Natural Science Foundation of China [21575050, 21777056]
  4. Natural Science Foundation of Shandong Province [ZR2019BB007, ZR2020QB097]
  5. Program for Scientific Research Innovation Team in Colleges and Universities of Shandong Province

向作者/读者索取更多资源

An ultrasensitive ECL biosensing platform for early diagnosis of procalcitonin was developed by enhancing ECL signal stability and utilizing dual-quenching strategies. The combination of NH2-MIL-101's catalytic performance and dual-quenching strategy provided dominant stability, selectivity, and reproducibility to the biosensor.
Herein, an ultrasensitive electrochemiluminescence (ECL) biosensing platform for early diagnosis of procalcitonin (PCT) was developed based on enhancing the stability of ECL signal and dual-quenching strategies. In this proposal, in order to improve the deficient of luminescence signal stability of semiconductor luminescent materials, the chromophore graphitic carbon nitride (g-C3N4) was loaded onto the MOF material (amine-functionalized MIL-101: NH2-MIL-101). Due to the excellent catalytic performance of NH2-MIL-101, more ECL reaction intermediate SO4 center dot- are restored from the co-reactant S2O82-, thus the ECL signal of g-C3N4 becomes stronger and more stable. With the aim of achieving detection of trace markers and improving sensor sensitivity, the dual-quenching strategy is carried out, which was achieved as follows: (i) the strong energy transfer between the donor of g-C3N4@NH2-MIL-101 and the acceptor of cobalt oxyhydroxide nanoflakes@gold nanoparticle (CoOOH@Au NPs) rational diminishes the ECL signal of g-C3N4; (ii) the perfect spectral overlap with the luminescent matrix achieves efficiency quenching through resonance energy transfer (RET). Benefiting from the ultrastability of luminophore and the reasonable dual quenching effect, the fabricated ECL biosensor presented dominant stability, selectivity and reproducibility accompanied by detection ranges from 0.014 pg/mL to 40 ng/mL and extremely low detection limit of 3.4 fg/mL. Consequently, it is worth believing that this method can provide a potential analytical strategy for trace immunoassay in clinical analysis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据