Concordance between creatinine- and cystatin C-based eGFR in clinical practice

出版社

TAYLOR & FRANCIS LTD
DOI: 10.1080/00365513.2021.1871776

关键词

Creatinine; cystatin C; eGFR; combined; accuracy; children

向作者/读者索取更多资源

Through analyzing 1596 simultaneous cystatin C and creatinine measurements in a pediatric nephrological population, it was found that the mean of eGFR(crea) and eGFR(cys) has high accuracy, with the majority of measurements having Delta eGFR below 40%. Measurements with Delta eGFR above 40% were more frequent in patients with neural tube defects, while potential explanations were found for measurements with low agreement.
The mean of GFR-estimates based on serum creatinine (eGFR(crea)) and cystatin C (eGFR(cys)) has superior accuracy than each estimate alone. Recent studies have shown that agreement between eGFR(crea) and eGFR(cys) is an indicator for the accuracy of the mean of the two estimates. As long as the difference between the two (|Delta eGFR|) is below 40%, a high P-30 accuracy rate of more than 90% was documented in research settings using gold-standard GFR measurements. This was the case in approximately 80% of the measurements. The study was set out to explore |Delta eGFR| in a broader pediatric nephrological population and identify factors influencing the discrepancy between eGFR(crea) and eGFR(cys). We retrospectively analyzed 1596 simultaneous cystatin C and creatinine measurements in 649 unique patients at the pediatric nephrology outpatient clinic of VU university medical center. The FASage equation was used to calculate eGFR(crea), FAScys for eGFR(cys). |Delta eGFR| was calculated as 100x(|eGFR(crea)-eGFR(cys)|)/(0.5x(eGFR(crea)+eGFR(cys)). Delta eGFR below 40% was considered high agreement. Patient characteristics like age, diagnosis, glucocorticosteroid use, eGFR, BMI and sex were analyzed for their effect on Delta eGFR below or above 40% using non-parametric tests and a potential explanation for measurements with low agreement was sought. Eighty-seven percent of the population had a |Delta eGFR| lower than 40%. Measurements with |Delta eGFR| above 40% were significantly more frequent from patients with neural tube defects. In 102 out of 208 measurements with low agreement, a potential explanation was found. In a broad pediatric nephrological population, |Delta eGFR| is below 40% in the vast majority of measurements. In this group, the mean of eGFR(crea) and eGFR(cys) can be used as an accurate estimate of GFR.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据