4.6 Article

A metal artifact reduction method for small field of view CT imaging

期刊

PLOS ONE
卷 16, 期 1, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0227656

关键词

-

资金

  1. Bio and Medical Technology Development Program of the National Research Foundation (NRF) - Ministry of Science and ICT [NRF-2019R1A2C2084936, 2020R1A4A1016619]
  2. Korea Medical Device Development Fund - Korea government (the Ministry of Science and ICT)
  3. Korea Medical Device Development Fund - Korea government (Ministry of Trade, Industry and Energy)
  4. Korea Medical Device Development Fund - Korea government (Ministry of Health AMP
  5. Welfare, Republic of Korea)
  6. Korea Medical Device Development Fund - Korea government (Ministry of Food and Drug Safety) [202011A03]

向作者/读者索取更多资源

Several sinogram inpainting based metal artifact reduction methods have been proposed, but existing methods are not effective in the presence of data truncation. This paper introduces a new MAR method that involves using a newly synthesized sinogram to reduce metal artifact effectively. The proposed method shows significant improvement in reducing residual metal artifacts compared to previous methods.
Several sinogram inpainting based metal artifact reduction (MAR) methods have been proposed to reduce metal artifact in CT imaging. The sinogram inpainting method treats metal trace regions as missing data and estimates the missing information. However, a general assumption with these methods is that data truncation does not occur and that all metal objects still reside within the field-of-view (FOV). These assumptions are usually violated when the FOV is smaller than the object. Thus, existing inpainting based MAR methods are not effective. In this paper, we propose a new MAR method to effectively reduce metal artifact in the presence of data truncation. The main principle of the proposed method involves using a newly synthesized sinogram instead of the originally measured sinogram. The initial reconstruction step involves obtaining a small FOV image with the truncation artifact removed. The final step is to conduct sinogram inpainting based MAR methods, i.e., linear and normalized MAR methods, on the synthesized sinogram from the previous step. The proposed method was verified for extended cardiac-torso simulations, clinical data, and experimental data, and its performance was quantitatively compared with those of previous methods (i.e., linear and normalized MAR methods directly applied to the originally measured sinogram data). The effectiveness of the proposed method was further demonstrated by reducing the residual metal artifact that were present in the reconstructed images obtained using the previous method.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据