4.2 Review

Predictive Ability of Direct Electrical Stimulation on Facial Nerve Function Following Vestibular Schwannoma Surgery: A Systematic Review and Meta-analysis

期刊

OTOLOGY & NEUROTOLOGY
卷 42, 期 4, 页码 493-504

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MAO.0000000000003007

关键词

-

向作者/读者索取更多资源

According to the study findings, MST values of 0.05 mA and 0.10 mA demonstrate sensitivity and specificity for facial function in the long term, while CMAP amplitude less than 500 mu V shows high sensitivity for poor short-term facial function. Other DES parameters may have the potential to accurately predict both short- and long-term postoperative facial function, although they have not been as extensively studied.
Objective: Facial nerve preservation is critical in vestibular schwannoma (VS) surgery. Direct electrical stimulation (DES) is a widely used method for intraoperative localization of the facial nerve and assessment of nerve integrity. We sought to assess the predictive ability of DES parameters on facial nerve function post-VS surgery. Databases reviewed: A systematic literature search of English-language studies published from 1946 to 2019 was undertaken using EMBASE, MedLine/PubMed, and the Cochrane Central Register of Controlled Trials. Methods: Included studies involved patients undergoing VS surgery and assessed predictive ability of any DES parameter on postoperative facial function. Two authors independently reviewed studies and extracted data. Meta-analysis of diagnostic accuracy of DES parameters was used to calculate pooled sensitivities and specificities of common cutoffs. For DES parameters reported by less than four studies, outcomes were reported descriptively. Results: A MST cutoff of 0.10 mA had sensitivity of 0.76 (95% CI 0.53-0.90) and specificity 0.68 (95% CI 0.42-0.87) for facial function in the long term, and MST 0.05 mA had sensitivity 0.73 (95% CI 0.58-0.84) and specificity 0.74 (95% CI 0.59-0.85). CMAP amplitude < 500 mu V had sensitivity of 0.87 (95% CI 0.78-0.93) for poor short-term facial function. Conclusions: A CMAP amplitude response < 500 mu V is sensitive for poor short-term facial function, whereas MST values of 0.05 mA and 0.10 mA are both sensitive and specific in the long term. Other DES parameters may be able to accurately predict both short- and long-term postoperative facial function, but have been less studied.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据