4.6 Article

Rapid measurement of the low contrast detectability of CT scanners

期刊

MEDICAL PHYSICS
卷 48, 期 3, 页码 1054-1063

出版社

WILEY
DOI: 10.1002/mp.14657

关键词

dose reduction; low-contrast detectability; quality assurance

资金

  1. UCLA Radiological Sciences Exploratory Research Program
  2. National Institutes of Health [U24EB028936]

向作者/读者索取更多资源

A new framework for objectively characterizing low contrast detectability (LCD) in computed tomography (CT) imaging was introduced, producing a machine LCD metric with more representative results. Experimental scans demonstrated the feasibility of the technique in measuring machine LCD with tight error bars using only a single scan, which could facilitate routine quality assurance and comparisons between different protocols and scanners.
Purpose: Low contrast detectability (LCD) is a metric of fundamental importance in computed tomography (CT) imaging. In spite of this, its measurement is challenging in the context of nonlinear data processing. We introduce a new framework for objectively characterizing LCD with a single scan of a special-purpose phantom and automated analysis software. The output of the analysis software is a machine LCD metric which is more representative of LCD than contrast-noise ratio (CNR). It is not intended to replace human observer or model observer studies. Methods: Following preliminary simulations, we fabricated a phantom containing hundreds of low-contrast beads. These beads are acrylic spheres (1.6 mm, net contrast similar to 10 HU) suspended and randomly dispersed in a background matrix of nylon pellets and isoattenuating saline. The task was to search for and localize the beads. A modified matched filter was used to automatically scan the reconstruction and select candidate bead localizations of varying confidence. These were compared to bead locations as determined from a high-dose reference scan to produce free-response ROC curves. We compared iterative reconstruction (IR) and filtered backpropagation (FBP) at multiple dose levels between 40 and 240 mAs. The scans at 60, 120, and 180 mAs were performed three times each to estimate uncertainty. Results: Experimental scans demonstrated the feasibility of our technique. Our metric for machine LCD was the area under the exponential transform of the FROC curve (AUC). AUC increased monotonically from 0.21 at 40 mAs to 0.84 at 240 mAs. The sample standard deviation of AUC was approximately 0.02. This measurement uncertainty in AUC corresponded to a change in tube current of 4% to 8%. Surprisingly, we found that AUCs for IR were slightly worse than AUCs for FBP. While the phantom was sufficient for these experiments, it contained small air bubbles and alternative fabrication methods will be necessary for widespread utilization. Conclusions: It is feasible to measure machine LCD using a search task on a phantom with hundreds of beads and to obtain tight error bars using only a single scan. Our method could facilitate routine quality assurance or possibly enable comparisons between different protocols and scanners.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据