Feasibility, Reproducibility, and Clinical Implications of the Novel Fully Automated Assessment for Global Longitudinal Strain

期刊

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.echo.2020.09.011

关键词

Echocardiography; Strain imaging; Global longitudinal strain; Automated assessment; Screening

资金

  1. National Health and Medical Research Council (Canberra, Australia)

向作者/读者索取更多资源

The study investigated the feasibility, reproducibility, and predictive value of automated strain analysis compared to semiautomated and manual assessment of GLS in 561 asymptomatic subjects. The automated GLS measurements were technically feasible, with shorter calculation times than manual assessment, but still required manual correction in a substantial number of cases. Automated GLS showed potential in predicting cardiac events, although its predictive value was inferior to semiautomated GLS.
Background: Despite evidence of its usefulness, measurement of global longitudinal strain (GLS) has not been widely accepted as a clinical routine, because it requires proficiency and is time consuming. Automated assessment of GLS may be the solution for this situation. The aim of this study was to investigate the feasibility, reproducibility, and predictive value of automated strain analysis compared with semiautomated and manual assessment of GLS. Methods: In this validation study, different methods for the assessment of GLS were applied to echocardiograms from 561 asymptomatic subjects (mean age, 71 6 5 years) with heart failure risk factors, recruited from the community. All patients had both data on follow-up outcomes (new heart failure and cardiac death) and interpretable echocardiographic images for strain analysis. Measurement of GLS was repeated using the same apical images with three different measurement packages as follows: (1) fully automated GLS (AutoStrain), (2) semiautomated GLS (automated, corrected by a trained investigator), and (3) manual GLS (standard manual assessment by a trained investigator). Results: AutoStrain measurements were technically feasible in 99.5% of patients. Calculation times for automated (0.5 +/- 0.1 min/patient) and semiautomated assessment (2.7 +/- 0.6 min/patient) were significantly shorter than for manual assessment (4.5 +/- 1.6 min/patient; P < .001 for both). Approximately 40% of patients were thought to need manual correction after automatic calculation of GLS. Therefore, there was considerable discordance between automated and semiautomated and manual GLS. Over a median of 12 months of followup, cardiovascular events (new heart failure and cardiac death) occurred in 66 patients (11.8%). Automated GLS showed the potential to correctly detect normal and abnormal systolic function and predict cardiac events; the predictive value was inferior to that of semiautomated GLS. Conclusions: A novel fully automated assessment for GLS may provide a technically feasible, rapidly reproducible, and clinically applicable means of assessing left ventricular function, but a substantial number of automatic traces still need manual correction by experts. At the present stage, the semiautomated approach using this novel automated software seems to provide a better balance between feasibility and clinical relevance.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据