Modelling approach for miniaturized receiving transducers with square membrane and small sized back plate

期刊

JOURNAL OF SOUND AND VIBRATION
卷 490, 期 -, 页码 -

出版社

ACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD
DOI: 10.1016/j.jsv.2020.115710

关键词

Miniaturized transducer; MEMS microphone; Rectangular membrane; Small sized back plate

资金

  1. Grant Agency of the Czech Technical University in Prague [SGS17/190/OHK3/3T/13]

向作者/读者索取更多资源

The paper aims to provide a suitable analytical approach for describing the behavior of a miniaturized square MEMS receiving transducer, optimizing sensitivity while maintaining a Cartesian geometry and minimum dimensions. The analytical method introduced in this study avoids difficulties of multi-modal analysis caused by geometrical discontinuity, and presents an approximate analytical solution for estimating sensitivity in the lower frequency range. The FEM solutions provided were used to test against the analytical results.
The objective of the paper is to provide a suitable analytical approach to describe the behaviour of a square miniaturised (MEMS) receiving transducer made up of a square membrane having the same dimensions as the external dimensions of the transducer itself, loaded by both a thin square small sized fluid-gap and a peripheral cavity connected together and set rear the membrane. This device departs from the other previous square devices in that the peripheral cavity is rear the membrane at the periphery of the backing plate (backing electrode). This architecture (derived from the circular one suggested previously) enables to optimize the sensitivity of the transducer while retaining both a cartesian geometry and the smallest dimensions possible (surface area and thickness). The analytical approach accounting for the effects of the interior geometrical discontinuity on the displacement field of the membrane used here to describe such square transducers (electrostatic or piezoelectric) departs from previous ones in that it avoids multi-modal analysis which exhibits procedural difficulties due to the coupling of Dirichlet-like (membrane) and Neumann-like (fluid) eigenfunctions (emphasized here by presence of the geometrical discontinuity in the fluid-filled part of the device). Additionally, an approximate analytical solution appropriate to express the displacement field of the membrane and to estimate the sensitivity with a good accuracy in the lower frequency range is presented. FEM solutions are provided, against which the analytical results have been tested. (C) 2020 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据