4.6 Article

Implications of dispersion in connecting capillaries for separation systems involving post-column flow splitting

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1639, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2021.461893

关键词

-

资金

  1. National Science Foundation [CHE-2003734, CHE-150815]
  2. Agilent Technologies Thought Leader Award
  3. Camille and Henry Dreyfus Foundation

向作者/读者索取更多资源

This study examines the impact of flow splitting on peak dispersion in liquid chromatography experiments. By conducting a series of experiments, it was found that the split ratio and post-split connecting tubing dimensions have a significant effect on peak dispersion. A simple view based on the conservation of mass was proposed to predict peak variances at the detector accurately.
It is common practice in liquid chromatography to split the flow of the effluent exiting the analytical column into two or more parts, either to enable parallel detection (e.g., coupling the separation to two destructive detectors such as light scattering and mass spectrometry (MS)), or to accommodate flow rate limitations of a detector (e.g., electrospray ionization mass spectrometry). In these instances the user must make choices about split ratio and dimensions of connecting tubing that is used between the split point and the detector, however these details are frequently not mentioned in the literature, and rarely justified. In our own work we often split the effluent following the second dimension (2D) column in two-dimensional liquid chromatography systems coupled to MS detection, and we have frequently observed post 2D column peak broadening that is larger than we would expect to result from dispersion in the MS ionization source itself. For the present paper we describe a series of experiments aimed at understanding the impact of the split ratio and post-split connecting tubing dimensions on dispersion of peaks exiting an analytical column. We start with the simple idea - based on the principle of conservation of mass - that analyte peaks entering the split point are split into two parts such that the analyte mass (and thus peak volume) entering and exiting the split point is conserved, and directly related to the ratio of flow rates entering and exiting the split point. Measurements of peak width and variance after the split point show that this simple view of the splitting process - along with estimates of additional dispersion in the post-split tubing - is sufficient to predict peak variances at the detector with accuracy that is sufficient to guide experimental work (median error of about 10% over a wide range of conditions). We feel it is most impactful to recognize that flow splitting impacts apparent post-column dispersion not because anything unexpected happens in the splitting process, but because the split dramatically reduces the volume of the analyte peak, which then is more susceptible to dispersion in connecting tubing that would not cause significant dispersion under conditions where splitting is not implemented. These results will provide practitioners with a solid basis on which rational decisions about split ratios and dimensions of post-split tubing can be made. (C) 2021 Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据