Charge variant analysis of protein-based biopharmaceuticals using two-dimensional liquid chromatography hyphenated to mass spectrometry

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1636, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2020.461786

关键词

Strong cation-exchange chromatography; Two-dimensional chromatography; Monoclonal antibodies; Biopharmaceuticals; Charge variant analysis; Mass spectrometry

资金

  1. Agilent Technologies [4068]

向作者/读者索取更多资源

The study developed a 2D-LC method for analyzing charge variants using strong cation-exchange chromatography as the first dimension separation.
The profile of charge variants represents an important critical quality attribute of protein-based biopharmaceuticals, in particular of monoclonal antibodies, and must therefore becontrolled. In this work, 2D-LC methods for charge variant analysis were developed using a strong cation-exchange chromatography (SCX) as first dimension (D-1) separation. Non-porous SCX (3 mu m) particle columns and different mobile phases were evaluated using a test mixture of some standard proteins of different size and p1 (comprising myoglobin, bovine serum albumin, cytochrome c, lysozyme and beta-lactoglobulin) and two monoclonal IgG1 antibodies (NIST mAb and Secukinumab). The most promising D-1 eluent for SCX was a salt-mediated pH-gradient system using a ternary mobile phase system with 2-(N-morpholino)ethanesulfonic acid, 1,3-diamino-2-propanol and sodium chloride. For the second dimension (D-2), a desalting reversed-phase liquid chromatography (RP-LC) was chosen to enable the hyphenation of the charge variant separation with mass spectrometric (MS) detection. While for intact mAbs the D-2 just served for desalting without additional selectivity, the D-2 contributed some orthogonal selectivity for the mAb fragment separation. Various core-shell and monolithic columns were tested and variables such as gradient time and flow rate systematically optimized. Unexpectedly, a C4 400 angstrom column (3.4 mu m diameter with 0.2 mu m porous shell) provided higher peak capacities compared to the same 1000 angstrom column (2.7 mu m diameter with 0.5 mu m porous shell). A thinner shell appeared to be more advantageous than wider pores under high flow regime. An ultra-fast RP-LC method with a run time of one minute was developed using trifluoroacetic acid which was later replaced by formic acid as additive for better MS compatibility. The successful hyphenation of the two orthogonal separation modes, SCX and RP-LC, could be demonstrated in the multiple heart-cutting and the full comprehensive mode. MS analysis using a high-resolution quadrupole time-of-flight instrument enabled to identify different glycoforms and some major charge variants of the antibody at the intact protein level as well as on the subunit level (Fc/2, Lc, Fd') in a middle-up approach by 2D-LC-ESI-MS analysis. (C) 2020 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据