4.2 Article

Temporary mechanical circulatory support prevents the occurrence of a low-output state in high-risk coronary artery bypass grafting: A case series

期刊

JOURNAL OF CARDIAC SURGERY
卷 36, 期 3, 页码 864-871

出版社

WILEY
DOI: 10.1111/jocs.15309

关键词

coronary artery bypass grafting; coronary artery disease; low-output state; mechanical circulatory support

资金

  1. Medical College of Wisconsin, Department of Surgery, Division of Cardiothoracic Surgery

向作者/读者索取更多资源

In this study, four patients with ischemic cardiomyopathy and left ventricular dysfunction underwent CABG with perioperative ventricular support using a microaxial tMCS device. All patients survived to device explant without device-related complications, demonstrating that perioperative tMCS may be a viable strategy for preventing postoperative low-output state in high-risk CABG patients with low complication rate and acceptable morbidity. Further investigation is needed to explore the impact of microaxial tMCS devices on perioperative outcomes and expand the indications for such devices.
Background Coronary artery bypass grafting (CABG) is a durable treatment for coronary artery disease. Left ventricular dysfunction (LVD) (a division of cardiothoracic surgery) (ejection fraction < 35%) significantly elevates perioperative risk for patients pursuing surgical revascularization. Periprocedural support with temporary mechanical circulatory support (tMCS) has shown benefit in this patient population. Methods Four patients with ischemic cardiomyopathy and LVD underwent CABG at our institution between 2017 and 2018. Each patient received perioperative ventricular support using a microaxial tMCS device (Impella 5.0 (R)). The occurrence of a postoperative low-output state (LOS) was assessed for as well as postoperative morbidity and mortality, device-specific complications, and tMCS support duration. Results All patients survived to device explant without device-related complications. Two patients required reoperation for nondevice-related bleeding. All patients were without an LOS at 24 h postoperatively with cardiac indices of 2.9-3.6 L/min/m(2), normalized serum lactate, and vasoactive-inotrope scores of 0-12.0. There was a notably high incidence of acute renal failure (50%), which was observed in patients with preoperative cardiogenic shock. One patient died 10 days after the device explant. Of the three patients that survived to discharge, two were alive at the most recent follow-up. Postoperative device support varied widely (0-500 h). Conclusion Perioperative tMCS may be a viable strategy for preventing postoperative LOS in high-risk CABG patients with a low complication rate and acceptable morbidity. The application of microaxial tMCS devices in CABG is an area that warrants further investigation to delineate its impact on perioperative outcomes and potentially expand the indications for such devices.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据