4.5 Article

Assessment of macrovascular and microvascular function in aging males

期刊

JOURNAL OF APPLIED PHYSIOLOGY
卷 130, 期 1, 页码 96-103

出版社

AMER PHYSIOLOGICAL SOC
DOI: 10.1152/japplphysiol.00616.2020

关键词

aging; flow-mediated dilation; EndoPAT; endothelial function; reactive hyperemia

资金

  1. National Institutes of Health [T32AG000279, R01AG049762]
  2. Colorado Clinical and Translational Sciences Institute [UL1 TR001082]
  3. Colorado Nutrition and Obesity Research Center [P30 DK048520]
  4. Eastern Colorado GRECC

向作者/读者索取更多资源

Aging is associated with reductions in endothelial function, assessed using brachial artery flow-mediated dilation. However, microvessel endothelial function assessed via finger plethysmography may not accurately reflect these age-related changes in large artery endothelial function. The relationship between peripheral artery tonometry and brachial artery ultrasound in evaluating endothelial function in the context of aging needs further investigation.
Aging is associated with reductions in endothelial function, observations primarily reported using brachial artery ultrasound. There is growing interest in the use of peripheral artery tonometry (PAT) of microvessels in the fingertip to assess endothelial function because it is less technically demanding and has a high sensitivity and specificity for assessing coronary endothelial function. Moreover, similar to brachial artery flow-mediated dilation (FMD), PAT predicts cardiovascular disease outcomes. However, the relationship between PAT and FMD have yet to be examined in the context of aging. To address this question, reactive hyperemic index (RHI) using EndoPAT and FMD using brachial artery ultrasound were assessed after 5 min of forearm ischemia in 20 younger (18-40yr old; 29 +/- 4yr) and 20 older (60-75 yr old; 65 +/- 4yr) healthy adult men. Higher values of both FMD and RHI indicate better endothelial function. Endothelial function assessed via brachial artery FMD was lower in older (4.8 +/- 2.1%), compared with younger (7.5 +/- 1.6%) men (P < 0.001). In contrast, the RHI assessed via PAT was greater in older (2.2 +/- 0.6), compared with younger (1.8 +/- 0.5) men (P = 0.014). FMD and RHI were not correlated (r = -0.15; P = 0.35). We conclude that PAT may not be an appropriate measure to evaluate age-associated changes in endothelial function. NEW & NOTEWORTHY Microvessel endothelial function assessed via finger plethysmography may not reflect age-associated reductions in large artery endothelial function assessed via brachial artery flow-mediated dilation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据