4.4 Article

Direct Evidence of Acetaminophen Interference with Subcutaneous Glucose Sensing in Humans: A Pilot Study

期刊

DIABETES TECHNOLOGY & THERAPEUTICS
卷 18, 期 -, 页码 43-47

出版社

MARY ANN LIEBERT, INC
DOI: 10.1089/dia.2015.0410

关键词

-

资金

  1. JDRF [DK29953, DK90541]
  2. National Institutes of Health [DK085516, DK DP3 094331]
  3. National Center for Advancing Translational Science, a component of the National Institutes of Health [UL1 TR000135]

向作者/读者索取更多资源

Background: Recent advances in accuracy and reliability of continuous glucose monitoring (CGM) devices have focused renewed interest on the use of such technology for therapeutic dosing of insulin without the need for independent confirmatory blood glucose meter measurements. An important issue that remains is the susceptibility of CGM devices to erroneous readings in the presence of common pharmacologic interferences. We report on a new method of assessing CGM sensor error to pharmacologic interferences using the example of oral administration of acetaminophen. Materials and Methods: We examined the responses of several different Food and Drug Administration-approved and commercially available CGM systems (Dexcom [San Diego, CA] Seven((R)) Plus, Medtronic Diabetes [Northridge, CA] Guardian((R)), and Dexcom G4((R)) Platinum) to oral acetaminophen in 10 healthy volunteers without diabetes. Microdialysis catheters were placed in the abdominal subcutaneous tissue. Blood and microdialysate samples were collected periodically and analyzed for glucose and acetaminophen concentrations before and after oral ingestion of 1g of acetaminophen. We compared the response of CGM sensors with the measured acetaminophen concentrations in the blood and interstitial fluid. Results: Although plasma glucose concentrations remained constant at approximately 90mg/dL (approximately 5mM) throughout the study, CGM glucose measurements varied between approximately 85 to 400mg/dL (from approximately 5 to 22mM) due to interference from the acetaminophen. The temporal profile of CGM interference followed acetaminophen concentrations measured in interstitial fluid (ISF). Conclusions: This is the first direct measurement of ISF concentrations of putative CGM interferences with simultaneous measurements of CGM performance in the presence of the interferences. The observed interference with glucose measurements in the tested CGM devices coincided temporally with appearance of acetaminophen in the ISF. The method applied here can be used to determine the susceptibility of current and future CGM systems to interference from acetaminophen or other exogenous pharmacologic agents.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据