4.5 Article

Electrochemical mineralization of abattoir wastewater with continuous system

出版社

SPRINGER
DOI: 10.1007/s13762-020-03109-w

关键词

Electrochemical oxidation; Abattoir wastewater; Wastewater treatment; Energy consumption; Organic pollutants; Kinetic model

资金

  1. [547698]

向作者/读者索取更多资源

This study investigated the effects of various operational parameters on the removal of pollutants from cattle-abattoir wastewater using a continuous electrochemical oxidation system. The optimal operating conditions for energy efficiency were determined to be a NaCl concentration of 1 M and an applied current density of 4.73 mA/cm(2). Under these conditions, removal efficiencies for various pollutants were found to be high, with the energy consumption calculated as 2.42 kWh/kg COD and 19.43 kWh/m(3). The approximate cost to treat 1 m(3) wastewater was calculated as $6.43. The kinetic behavior followed a pseudo-first-order model.
This study aims to determine the effects of initial pollutant concentration level (1/1-1/4), flow rate (10-40 mL/min), NaCl concentration (0.1-1 M), pH (3-9) and current density (4.73-23.67 mA/cm(2)) parameters on the removals of total suspended solids, total organic carbon, chemical oxygen demand, total nitrogen and color for economic treatment of cattle-abattoir wastewater using mesh-type Ti/Pt anodes with continuous EO system. Total suspended solids, total organic carbon, chemical oxygen demand, total nitrogen and color analyses were carried out according to photometric method, catalytic oxidation method, closed reflux colorimetric method, nitrogen cell test method and platinum-cobalt method, respectively. The effluent chloride levels were analyzed according to the argentometric titration method. According to results, all operational parameters had an impact on removal efficiencies but the most effective parameters on energy consumption were NaCl concentration and applied current density. Although two possible system conditions were determined according to removal efficiencies the operating conditions with the lowest energy consumption are considered to be optimal. The optimum operating conditions were determined as NaCl concentration of 1 M, CD of 4.73 mA/cm(2), initial pH of 7.03, reaction temperature of 25 degrees C and FR of 10 mL/min. Under these conditions removal efficiencies (%) for total suspended solids, total organic carbon, chemical oxygen demand, total nitrogen and color were found as; 98.28, 93.03, 97.44, 95.53 and 99.80, respectively. The energy consumption values were calculated as 2.42 kWh/kg COD and 19.43 kWh/m(3). The approximate cost to treat 1 m(3) wastewater was calculated as $ 6.43. The kinetic behavior abided by a pseudo-first-order model.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据