4.7 Article

Method to Reduce Quantization Error in Direct Interface Circuits for Resistive Sensors

期刊

IEEE SENSORS JOURNAL
卷 20, 期 23, 页码 13910-13918

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2020.2971315

关键词

Direct interface circuits; calibration methods; error analysis; quantization error; resistive sensor; interface sensor; time-based measurement

资金

  1. Spanish Government
  2. European ERDF Program Funds [TEC2015-67642-R]
  3. Universidad de Malaga under Program Plan Propio 2018

向作者/读者索取更多资源

Reading resistive sensors and converting their information to digital values is a matter of great interest in practical applications. Direct Interface Circuits (DICs) perform this task efficiently through a resistance-to-time-to-digital conversion. The main benefit of this type of circuit is the simplicity of its design and the accuracy of the results. However, one of its drawbacks is that quantization errors in the measurements seriously compromise accuracy if the information is not converted using a high-frequency clock or with high capacitor values. To avoid this situation, this article presents a new type of DIC with the same passive elements as a classic DIC, but which uses a high value resistor in the final instant of the resistance-to-time conversion. The circuit has been implemented using a commercial FPGA with the capture module operating at different clock frequencies. The results show that relative errors in measuring resistors of up to 33 Omega decrease to 1.56% when operating with a 12.5 MHz timer.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据