4.4 Article

Natural convection heat transfer performance of additively manufactured tube bundle heat exchangers with novel fin design

期刊

HEAT AND MASS TRANSFER
卷 57, 期 7, 页码 1193-1203

出版社

SPRINGER
DOI: 10.1007/s00231-020-03014-5

关键词

-

资金

  1. Projekt DEAL

向作者/读者索取更多资源

The study investigated the heat transfer performance of a novel finned heat exchanger design, revealing that integrated pin fin designs can enhance heat conduction and air-side heat transfer efficiency. SIPF showed higher Nusselt number compared to CPF, while CIPF had a lower Nusselt number. The 2-row configuration achieved higher thermal performance and SIPF proved to have better compactness compared to CPF.
We studied the heat transfer of finned heat exchanger configurations with a novel design. These novel fin designs use integrated pins to enhance the heat conduction from the fin base to the fin tip as well as the air-side heat transfer on the fin surface. Oval tubes with conventional circular plain fins (CPF) as well as novel circular integrated pin fins (CIPF) and serrated integrated pin fins (SIPF) were additively generated by a Selective Laser Melting (SLM) process and installed at the bottom of a 6.5 m long chimney. All heat exchanger designs were tested in a 2-row and 3-row configuration with Rayleigh numbers between 25,000 and 120,000. We found the average Nusselt number of SIPF to be higher and the Nusselt number of the CIPF to be lower than for the CPF. Moreover, the 2-row configuration achieved a higher Nusselt number compared to the 3-row configuration for all heat exchanger designs. The analysis of the individual tube rows showed the highest Nusselt numbers at the first tube row and the lowest one at the last tube row for both configurations. However, for the SIPF the difference between the first and second tube row is smaller compared to the CPF and CIPF. In order to evaluate the compactness of the heat exchanger, the volumetric heat flux density was considered. Similar to Nusselt number the volumetric heat flux density enhanced for the SIPF and reduced for the CIPF compared to the conventional design. Also the 2-row configuration reached greater thermal performance compared to the 3-row configuration. Additionally, the volume and the surface area of the heat exchanger are 6.9% and 30.7% lower for the SIPF compared to the CPF. The experimental data were used to develop an empirical heat transfer correlation between Nusselt number, Rayleigh number, fin design and tube row number.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据