4.7 Article

Hybrid surrogate model for online temperature and pressure predictions in data centers

出版社

ELSEVIER
DOI: 10.1016/j.future.2020.08.029

关键词

Data center; Data-driven models; Row-based cooling architecture; Temperature prediction; ANN; SVR

资金

  1. Natural Sciences and Engineering Research Council (NSERC) of Canada

向作者/读者索取更多资源

The study focuses on the issues in data center design and operation, and develops a hybrid surrogate model to accurately predict temperature distribution within a data center. By combining data-driven models and thermofluid transport relations, more effective optimization of airflow distribution, reduced energy consumption, and improved cooling configuration design in data centers can be achieved.
The increase in cloud computing and big data storage has led to significant growth in data center (DC) infrastructure that is now estimated to consume more than 1.5% of the world's electricity. Due to suboptimal DC design and operation, a significant fraction of this energy is wasted because of the cooling systems inability to effectively distribute cold air to servers. Consequently, additional cooling air must be circulated inside a DC to prevent local hot spots, which leads to undercooling at other locations. Row-based cooling is an emerging architecture that provides more effective airflow distribution, which lowers energy consumption. Since available methods are unsuitable for accurate online predictions, a general thermal model is required to predict spatiotemporal temperature changes inside a DC and hence optimize airflow distribution for this architecture. Typical approaches include physical models, computational fluid dynamics (CFD) simulations, and black-box data-driven models (DDMs). All three approaches are limited because they do not encapsulate the entirety of relevant operational parameters, are time-consuming and can provide unacceptable errors during extrapolative predictions. We address these deficiencies by developing a fast, adaptive, and accurate hybrid surrogate model by combining a DDM and the thermofluid transport relations to predict temperatures in a DC. Training data for the DDM is obtained from CFD simulations. An artificial neural network (ANN) with the Rectified Linear Unit (ReLU) activation function is shown to predict pressure distributions accurately in a row-based cooling DC. These predicted pressures are inputs for thermofluid transport equations to determine the temperature distribution. The applicability of the model is demonstrated by comparing predictions with experimental measurements that characterize the influence of varying server workload distribution and cooling unit operational conditions, i.e., temperature set-point, airflow rate, and fan locations, on the temperature distribution. The model can be used to (1) improve cooling configuration design, (2) facilitate thermally aware workload management, and (3) test what if scenarios to characterize the influence of operating conditions on the temperature distribution. (C) 2020 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据