4.5 Article

Measuring body condition of lizards: a comparison between non-invasive dual-energy X-ray absorptiometry, chemical fat extraction and calculated indices

期刊

FRONTIERS IN ZOOLOGY
卷 18, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12983-020-00382-w

关键词

-

类别

资金

  1. Israel Science Foundation

向作者/读者索取更多资源

Condition indices (CIs) are used in ecological studies to measure the health and fitness of individual animals, often validated invasively by fat extraction. Dual-energy X-ray absorptiometry (DXA) allows for non-destructive analysis of body composition and multiple measurements. This study calibrated DXA against a chemical extraction of fat and found that the ratio of body mass to SVL is the most accurate body condition estimator for this species.
Background Condition indices (CIs) are used in ecological studies as a way of measuring an individual animal's health and fitness. Noninvasive CIs are estimations of a relative score of fat content or rely on a ratio of body mass compared to some measure of size, usually a linear dimension such as tarsus or snout-vent length. CIs are generally validated invasively by lethal fat extraction as in a seasonal sample of individuals in a population. Many alternatives to lethal fat extraction are costly or time consuming. As an alternative, dual-energy X-ray absorptiometry (DXA) allows for non-destructive analysis of body composition and enables multiple measurements during an animal's life time. DXA has never been used for ecological studies in a small, free-ranging lizard before, therefore we calibrated this method against a chemical extraction of fat from a sample of 6 geckos (Israeli fan toed gecko Ptyodactylus guttatus) ranging in body mass between 4.2-11.5 g. We then used this calibrated DXA measurements to determine the best linear measurement calculated CI for this species. Results We found that fat mass measured with DXA was significantly correlated with the mass of chemically extracted fat for specimens more than 4.8 g (N = 5, R-2 = 0.995, P < 0.001). Fat percentage regressed with body mass significantly predicted the DXA fat percentage (N = 29, R-adj.(2) = 0.862, p < 0.001). Live wet mass was significantly correlated with predicted fat mass (N = 30, R-2 = 0.984, P < 0.001) for specimens more than 4.8 g. Among the five calculated non-invasive CIs that we tested, the best was mass/SVL. Conclusions We recommend that in situations where DXA cannot be used, that the most accurate of the body condition estimators for this species is mass/SVL (snout-vent length) for both sexes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据