4.7 Article

Between- and within-individual variability of urinary phthalate and alternative plasticizer metabolites in spot, morning void and 24-h pooled urine samples

期刊

ENVIRONMENTAL RESEARCH
卷 191, 期 -, 页码 -

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.envres.2020.110248

关键词

Variability; ICC; Alternative plasticizers; Phthalates; Urine; Biomonitoring

资金

  1. Ministry of the Flemish Community (Department of Economics, Science and Innovation)
  2. Ministry of the Flemish Community (Flemish Agency for Care and Health)
  3. Ministry of the Flemish Community (Department of Environment, Nature and Energy)
  4. Research Foundation Flanders [G0E5216N]
  5. University of Antwerp

向作者/读者索取更多资源

Due to international regulations, commonly used phthalates such as di(2-ethylhexyl) phthalate (DEHP) are being replaced by other phthalates, such as di-isononyl phthalate (DINP), and di-isodecyl phthalate (DIDP) and by alternative plasticizers (APs) with similar chemical characteristics, like di(isononyl)cyclohexane-1,2-dicarboxylate (DINCH), di(2-ethylhexyl) terephthalate (DEHTP), or di-(2-ethylhexyl) adipate (DEHA). Urinary concentrations of metabolites are frequently used in the exposure assessment of non-persistent chemicals and for biomonitoring purposes, the intra- and inter-day variability of the metabolites should be known. However, the short-term variability of AP and several phthalate biomarkers has not been investigated yet. In this study, we collected all spot samples from 10 healthy adults for 5 consecutive days and 24h pooled urine on one additional day to investigate the short-term variability of 22 biomarkers of phthalates and APs. Metabolites of DEP, DEHP, DiBP, DnBP, DBzP, DINP and DIDP were found in high detection frequencies, while metabolites of most APs were found in approximately 50% of the samples. The short-term reproducibility of metabolites with diet as primary source (DEHP, DINP, DIDP) was poor (intraclass correlation coefficient - ICC < 0.4), whereas biomarkers of DEP, DnBP, DiBP and BBzP showed good consistency, most likely due to more continuous sources resulting in less between-day variance. ICC values of AP metabolites were similar to those of DEHP, but more studies are required to confirm these findings. Overall, reproducibility improved considerably when values were corrected for urinary dilution and when only morning voids samples were considered. Levels in morning voids samples were consistent for 5 days and comparable to 24-h pooled urine for all metabolites except for OH-MEHTP, sum DINP and sum DIDP, which supports the use of morning voids in human biomonitoring studies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据