The research focused on the application of Composite Plate Shear Wall/Concrete Filled as core-wall structures in high-rise buildings, with a particular emphasis on investigating their cyclic lateral load behavior, strength, and drift capacity. Valuable insights were gained through large-scale testing simulations to support the development of design guidelines for high-rise core-wall steel buildings.
A Composite Plate Shear Wall/Concrete Filled (C-PSW/CF) is a special lateral-force resisting system consisting a sandwiched panel of two steel plates with concrete infill in between them, ideally suited for core-wall structures in high-rise construction. The steel plates are connected to each other using tie bars that are embedded in the concrete infill and, in some instances, steel-headed stud anchors. This research project was conducted to investigate the cyclic lateral load behavior of these walls, in terms of strength, and drift capacity. The testing program includes two large-scale C-shaped concrete filled composite plate shear core walls subjected to flexure and axial loads together. Their dimensions were the same, but different axial loads were applied up to 19% of axial loading capacity. The composite behavior and the plastic hinge development were investigated and compared to results from plastic moment calculations. This provides valuable results on the expected behavior of one composite cross-section that is frequently used in full core wall. This is done to support the development of design guidelines for high-rise core-wall steel buildings having C-PSW/CF as the primary lateral force resisting system.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据