4.7 Article Proceedings Paper

Design of optimal heat exchanger network with fluctuation probability using break-even analysis

期刊

ENERGY
卷 212, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.energy.2020.118583

关键词

Break-even Analysis; Fluctuation Probability; Pinch Analysis; Heat Exchanger Network; Maximum Energy Recovery; Economical

资金

  1. Universiti Teknologi Malaysia (UTM) [Q.J130000.3509.05G96, Q.J130000.2509.19H34, Q.J130000.2409.08G86, CZ.02.1.01/0.0/0.0/15_003/0000456]
  2. EC project for Sustainable Process Integration Laboratory-SPIL - Czech Republic Operational Program Research and Development, Education [CZ.02.1.01/0.0/0.0/15_003/0000456]

向作者/读者索取更多资源

Heat exchanger network (HEN), which is designed to achieve the maximum energy recovery (MER) involves the integration and interactions of multiple process streams. In a plant, the system operation may experience various disturbances such as changes in supply temperature and flowrates. Small disturbances on one stream can affect other connecting streams. To manage these disturbances, the process to process and utility heat exchangers with bypass streams installation are typically overdesigned, leading to higher capital investment. This study presents the cost optimisation of flexible MER HEN design which considers the fluctuation probability using Break-Even Analysis (BEA). Stream data is extracted for the Pinch study and assessment for flexibility and MER was performed. The MER heat exchanger maximum size (MER-HEM) able to handle the most critical supply temperature fluctuations while minimising the utility consumption is calculated. However, the overdesign factor can affect the total annualised cost (TAC) at a certain probability of fluctuation occurrence. Besides that, the fluctuations experienced by the stream can result in the utility increasing or decreasing. Therefore, the MER heat exchanger original size (MER-HEO) is favoured when the fluctuation resulted in the utility cost increasing. The BEA is performed to determine the probability that results in high savings of the TAC and developed an optimal HEN design of MER-HEM or MER-HEO. The break-even point (BEP) from BEA indicate the exact fluctuation probability at which the TAC of MER-HEM and MER-HEO is the same. A case study with fluctuation probability over one-year operation is used to demonstrate the methodology. Application of the proposed methodology on the case study shows that the optimum size of heat exchanger can be determined and the additional savings of TAC can be achieved. (C) 2020 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据