4.7 Article

Monitoring arsenic using genetically encoded biosensors in vitro: The role of evolved regulatory genes

期刊

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.ecoenv.2020.111273

关键词

Toxic pollutant; Genetically encoded biosensors; In vitro; Evolved regulatory genes; Arsenic

资金

  1. National Natural Science Foundation of China [21707144]
  2. Anhui Provincial Natural Science Foundation [1808085QB49, 1808085QB37]
  3. Anhui Provincial Key RD Programmes [202004i07020016]
  4. Key Program of 13th five-year plan, CASHIPS [KP-2017-05]
  5. Opening Foundation of Anhui Province of Key Laboratory of Environmental Toxicology and Pollution Control Technology [Y79AH72588]

向作者/读者索取更多资源

This study successfully established a genetically encoded biosensor in vitro for arsenic detection using ArsR and GFP genes. An evolved ArsR mutant, ep3, was found to respond to arsenic and regulate GFP expression. A standard procedure for in vitro arsenic detection was established based on detailed experimental analysis.
Toxic pollutant (TP) detection in situ using analytical instruments or whole-cell biosensors is inconvenient. Designing and developing genetically coded biosensors in vitro for real-world TP detection is a promising alternative. However, because the bioactivity and stability of some key biomolecules are weakened in vitro, the response and regulation of reporter protein become difficult. Here, we established a genetically encoded biosensor in vitro with an arsenical resistance operon repressor (ArsR) and GFP reporter gene. Given that the wildtype ArsR did not respond to arsenic and activate GFP expression in vitro, we found, after screening, an evolved ArsR mutant ep3 could respond to arsenic and exhibited an approximately 3.4-fold fluorescence in-crease. Arsenic induced expression of both wildtype ArsR and ep3 mutant in vitro, however, only ep3 mutant regulated the expression of reporter gene. Furthermore, the effects of cell extracts, temperature, pH, incubation, and equilibrium time were investigated, and the equilibration of reaction mixtures for 30 min at 37 degrees C was found to be essential for in vitro arsenic detection prior to treatment with arsenic. Based on our data, we established a standard procedure for arsenic detection in vitro. Our results will facilitate the practical application of genetically encoded biosensors in TP monitoring.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据