4.3 Article

Flow cytometry: An accurate tool for screening P2RX7 modulators

期刊

CYTOMETRY PART A
卷 99, 期 8, 页码 793-806

出版社

WILEY
DOI: 10.1002/cyto.a.24287

关键词

drug discovery; flow cytometry; imaging flow cytometry; P2RX7; screening; spectral cytometry

资金

  1. Centre National de la Recherche Scientifique
  2. Institut National de la Sante et de la Recherche Medicale
  3. Institut National Du Cancer
  4. University of Lille

向作者/读者索取更多资源

P2RX7 is a poorly selective ATP-gated ion channel with important physiological and pathological implications, making it a potential therapeutic target in several diseases. Novel screening methods based on flow cytometry and spectral flow cytometry have been developed to efficiently measure P2RX7 activity and assess the efficacy of modulators. Spectral cytometry appears to be a useful tool for drug candidate screening by simultaneously evaluating multiple biological activities and correcting for the autofluorescence of compounds screened.
The P2X purinergic receptor 7 (P2RX7) is a poorly selective ATP-gated ion channel. Although P2RX7 binds ATP with relatively low affinity, prolonged activation can lead to nonselective membrane pore formation. Indeed, brief exposure to ATP triggers a rapid Ca2+ influx, whereas prolonged exposure to high ATP concentrations results in the passage of larger organic molecules. P2RX7 is involved in the physiopathology of a number of diseases and has notably emerged as a potential therapeutic target in inflammation, neuropathic pain, Alzheimer's disease, and cancer-prompting growing interest in the synthesis of novel P2RX7 modulators and the development of reliable, stringent screening methods. In the present study, we developed methods based on conventional flow cytometry, imaging flow cytometry and spectral flow cytometry and used them to measure P2RX7's activity upon activation by 3'-O-(4-benzoyl)benzoyl ATP. We also demonstrated the use of the highly sensitive DNA-intercalating dye TO-PRO-3 to determine P2RX7's large pore activity. The simultaneous quantification of calcium influx (Fluo-3 AM), large pore opening (TO-PRO-3), and viability (propidium iodide) is a very efficient method for low- to medium-throughput screening of P2RX7 modulators. Agonist and antagonist potencies can be accurately evaluated. Spectral cytometry notably enabled us to assay several biological activities while correcting for the intrinsic fluorescence of the screened compounds-otherwise a well-known limitation of fluorescence-based screening. Hence, spectral cytometry appears to be a useful, novel tool for drug candidate screening.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据