4.5 Article

Sacral neuromodulation with the InterStim™ system for faecal incontinence: results from a prospective French multicentre observational study

期刊

COLORECTAL DISEASE
卷 23, 期 6, 页码 1463-1473

出版社

WILEY
DOI: 10.1111/codi.15507

关键词

faecal incontinence; real‐ world data; sacral neuromodulation

资金

  1. Medtronic

向作者/读者索取更多资源

This study confirms the clinical effectiveness, safety, and positive effect of sacral neuromodulation with the InterStim(TM) system for the treatment of faecal incontinence, showing significant improvements in quality of life and symptoms with high patient satisfaction. Main device-related adverse events include the need for reprogramming, infection, and surgical revision.
Aim The aim of this work was to evaluate the effectiveness, patient satisfaction and quality of life (QoL) and the safety of sacral neuromodulation (SNM) with the InterStim(TM) system for the treatment of faecal incontinence (FI) and establish whether results published predominantly by expert sites are generalisable. Method This is a prospective, multicentre, observational study that invited all French sites treating FI with the InterStim (TM) system to enrol subjects indicated for an SNM therapy evaluation. Data were collected at three follow-up visits within 1 and 15 months. Therapeutic effectiveness was evaluated by the reduction in leakages per week and improvements over time in the ability to defer defaecation and QoL (as measured with the Faecal Incontinence Quality of Life score). Safety was assessed through reported adverse events. Results A total of 221 subjects with a mean age of 62.1 years were tested (184 women) and 178 received a permanent implant. For all implanted subjects with diary data at baseline and follow-up, a reduction in leakage of more than 50% was observed in 80%, 76% and 83% at 1-3, 4-8 and 9-15 months, respectively. The mean number of leakage episodes and urgency improved significantly compared with the baseline (p < 0.0001). Subjects showed improvements in QoL and time to defer defaecation and were generally satisfied with their therapy. The main device-related adverse event was the requirement to undertake reprogramming (in 52% of subjects with actions following an event). The rates of infection (in 6% of subjects) and surgical revision (in 10% of subjects) were in agreement with literature reports. Conclusion This study confirms the clinical effectiveness, safety and positive effect of SNM on QoL as well as high patient satisfaction for the treatment of FI in real-life.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据