4.5 Article

Developing and validating models to predict sudden death and pump failure death in patients with heart failure and preserved ejection fraction

期刊

CLINICAL RESEARCH IN CARDIOLOGY
卷 110, 期 8, 页码 1234-1248

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00392-020-01786-8

关键词

Heart failure; Sudden death; Pump failure death; Risk; Model

向作者/读者索取更多资源

The clinical models can predict risks for SD and PFD separately with good discrimination and calibration in HFpEF and are robust in external validation. Adding NT-proBNP further improved model performance. These models may help to identify high-risk individuals for device intervention in future trials.
Background Sudden death (SD) and pump failure death (PFD) are leading modes of death in heart failure and preserved ejection fraction (HFpEF). Risk stratification for mode-specific death may aid in patient enrichment for new device trials in HFpEF. Methods Models were derived in 4116 patients in the Irbesartan in Heart Failure with Preserved Ejection Fraction trial (I-Preserve), using competing risks regression analysis. A series of models were built in a stepwise manner, and were validated in the Candesartan in Heart failure: Assessment of Reduction in Mortality and morbidity (CHARM)-Preserved and Treatment of Preserved Cardiac Function Heart Failure with an Aldosterone Antagonist (TOPCAT) trials. Results The clinical model for SD included older age, men, lower LVEF, higher heart rate, history of diabetes or myocardial infarction, and HF hospitalization within previous 6 months, all of which were associated with a higher SD risk. The clinical model predicting PFD included older age, men, lower LVEF or diastolic blood pressure, higher heart rate, and history of diabetes or atrial fibrillation, all for a higher PFD risk, and dyslipidaemia for a lower risk of PFD. In each model, the observed and predicted incidences were similar in each risk subgroup, suggesting good calibration. Model discrimination was good for SD and excellent for PFD with Harrell's C of 0.71 (95% CI 0.68-0.75) and 0.78 (95% CI 0.75-0.82), respectively. Both models were robust in external validation. Adding ECG and biochemical parameters, model performance improved little in the derivation cohort but decreased in validation. Including NT-proBNP substantially increased discrimination of the SD model, and simplified the PFD model with marginal increase in discrimination. Conclusions The clinical models can predict risks for SD and PFD separately with good discrimination and calibration in HFpEF and are robust in external validation. Adding NT-proBNP further improved model performance. These models may help to identify high-risk individuals for device intervention in future trials.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据